The Update
Xpress
System Pack Installer
The Update
Xpress
System Pack Installer detects supported and installed device
drivers and firmware in the server and installs available updates.
For additional information and to download the Update
Xpress
System Pack
Installer, go to the ToolsCenter for System x and BladeCenter at
http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/ and click
UpdateXpress
System Pack Installer
.
Using the integrated management module
The integrated management module (IMM) is a second generation of the functions
that were formerly provided by the baseboard management controller hardware. It
combines service processor functions, video controller, and remote presence
function in a single chip.
The IMM supports the following basic systems-management features:
v
Active Energy Manager.
v
Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail).
v
Auto Boot Failure Recovery (ABR).
v
Automatic microprocessor disable on failure and restart in a two-microprocessor
configuration when one microprocessor signals an internal error. When one of
the microprocessors fail, the server will disable the failing microprocessor and
restart with the other microprocessor.
v
Automatic Server Restart (ASR) when POST is not complete or the operating
system hangs and the operating system watchdog timer times-out. The IMM
might be configured to watch for the operating system watchdog timer and
reboot the system after a timeout, if the ASR feature is enabled. Otherwise, the
IMM allows the administrator to generate a nonmaskable interrupt (NMI) by
pressing an NMI button on the light path diagnostics panel for an
operating-system memory dump. ASR is supported by IPMI.
v
A virtual media key, which enables remote presence support (remote video,
remote keyboard/mouse, and remote storage).
v
Boot sequence manipulation.
v
Command-line interface.
v
Configuration save and restore.
v
DIMM error assistance. The Unified Extensible Firmware Interface (UEFI)
disables a failing DIMM that is detected during POST, and the IMM lights the
associated system error LED and the failing DIMM error LED.
v
Environmental monitor with fan speed control for temperature, voltages, fan
failure, power supply failure, and power backplane failure.
v
Intelligent Platform Management Interface (IPMI) Specification V2.0 and
Intelligent Platform Management Bus (IPMB) support.
v
Invalid system configuration (CONFIG) LED support.
v
Light path diagnostics LEDs indicators to report errors that occur with fans,
power supplies, microprocessor, hard disk drives, and system errors.
v
Local firmware code flash update
v
Nonmaskable interrupt (NMI) detection and reporting.
v
Operating-system failure blue screen capture.
v
PCI configuration data.
114
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 811: ...Taiwan Class A compliance statement Notices 793 ...
Page 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 819: ......