Basic and Extended Configuration Status Register Codes
BCS
ECS
Explanation and possible recovery action
Code
not in
table
Code
not in
table
Explanation:The ServeRAID controller is not functioning properly.
Action:Have the system serviced.
00
01
Explanation:Invalid flash configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the system serviced.
00
02
Explanation:Invalid NVRAM configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the system serviced.
00
03
Explanation:Invalid flash and NVRAM configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the system serviced.
01
08
Explanation:No configuration was found in drives, or Online/Rebuild drives are not responding.
Action:Press F4, F5, F7, or F10.
01
18
Explanation:No configuration was found in drives, or Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
Action:Press F4, F5, F7, or F10.
01
28
Explanation:No configuration was found in drives, or Online/Rebuild and Ready/Standby drives
are not responding.
Action:Press F4, F5, F7, or F10.
01
38
Explanation:No configuration was found in drives, or Online/Rebuild, Hot-Spare/Standby
Hot-Spare, and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
01
48
Explanation:No configuration was found in drives, or Online/Rebuild drives are not responding
and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
58
Explanation:No configuration was found in drives, or Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
68
Explanation:No configuration was found in drives, or Online/Rebuild and Ready/Standby drives
are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
78
Explanation:No configuration was found in drives, or Online/Rebuild, Hot-Spare/Standby
Hot-Spare, and Ready/Standby drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
132
IBM
®
Netfinity
®
User’s Reference: ServeRAID
™
-4H Ultra160 SCSI Controller
Summary of Contents for Netfinity ServeRAID-4H Ultra160
Page 1: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Page 2: ......
Page 3: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Page 12: ...x IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 26: ...12 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 74: ...60 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 86: ...72 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 90: ...76 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 92: ...78 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 106: ...92 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 114: ...100 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 120: ...106 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 191: ......