BCS
ECS
Explanation and possible recovery action
07
18
Explanation:Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, or F10.
07
1C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
28
Explanation:Online/Rebuild and Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
07
2C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and a drive was
found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
38
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding.
Action:Press F4, F5, or F10.
07
3C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and a drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
48
Explanation:Online/Rebuild drives are not responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
4C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
58
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and
unidentified drives were found.
Action:Press F4, F5, or F10.
07
5C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, a
drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
68
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and unidentified
drives were found.
Action:Press F4, F5, or F10.
07
6C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, a drive was found at
the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
78
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
7C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, a drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
134
IBM
®
Netfinity
®
User’s Reference: ServeRAID
™
-4H Ultra160 SCSI Controller
Summary of Contents for Netfinity ServeRAID-4H Ultra160
Page 1: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Page 2: ......
Page 3: ...IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller SC00 N913 20...
Page 12: ...x IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 26: ...12 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 74: ...60 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 86: ...72 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 90: ...76 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 92: ...78 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 106: ...92 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 114: ...100 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 120: ...106 IBM Netfinity User s Reference ServeRAID 4H Ultra160 SCSI Controller...
Page 191: ......