/S:
drive+path
Specifies the drive and path to install
from
. This is the directory to which the
files were copied.
/T:
drive
Specifies the drive to install
to
. Default
is the current startup drive.
/TU:
drive+path
Specifies the drive and path of the
CONFIG.SYS file to update. The
default is to change the CONFIG.SYS
in the root directory of the drive
specified in the /T parameter (or the
startup drive). This parameter is
ignored if the
ChangeConfig
parameter
in the response file is FALSE.
For example, the line: NETFINST
/R:NETFBASE.RSP /S:Y:\NETFIN/T:C
/TU:D:\
will install Netfinity Manager, using the
options in the response file
NETFBASE.RSP, from the directory
Y:\NETFIN, to drive C: (the directory to
which the files are installed is taken
from the response file), and will modify
the CONFIG.SYS file in the D:\
directory.
Note:
For information on how to use a CID-enabled
software distribution manager, refer to the
publications provided with the individual
CID-enabled product.
Customized installation
For security reasons, not all users might need to have
access to all services. User access can be restricted by
creating a customized installation that will prevent some
services from being installed.
To create a customized installation, the INSTALL.INI file
must be edited. For example, when creating a customized
Netfinity Manager for Windows 95 or NT installation, edit
the INSTALL.INI file that is found on Netfinity Manager
directory.
The INSTALL.INI file has three sections, separated by the
line
[==]
The first section contains the installation configuration that
can be selected during installation. There can be no more
than eight choices. Each choice takes up two lines. The
150
: Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y,
41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Summary of Contents for Netfinity 5100 8658 21Y
Page 1: ...Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY S10K 2615 00...
Page 10: ...x Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 26: ...16 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 50: ...40 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 65: ...13 PCI slot 2 32 bit J32 Installing options 55...
Page 195: ...Parts listing Type 8658 Copyright IBM Corp 2000 185...
Page 196: ...186 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 215: ...Related service information 205...
Page 216: ...206 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 217: ...Related service information 207...
Page 218: ...208 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 219: ...Related service information 209...
Page 220: ...210 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 221: ...Related service information 211...
Page 222: ...212 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 235: ...Related service information 225...
Page 236: ...226 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 237: ...Related service information 227...
Page 245: ......
Page 246: ...Part Number 10K2615 Printed in U S A S10K 2615 00 1P P N 10K2615...