6. Follow the instructions that are given by the setup
wizard until the program is installed.
7. Restart the server.
To install the IBM PCI Hot Plug Solution package:
1. Download the IBM PCI Hot Plug Services EXE file from
the Netfinity Support web page and extract the files
onto a diskette.
2. Log on to Windows NT Server as a user in the
Administrator group.
3. Insert the diskette into the diskette drive.
4. From the Start menu, select the
Run
option.
5. Type A:\SETUP.EXE in the Open box.
6. Click
OK
. The Setup wizard opens.
7. Follow the instructions given by the setup wizard until
the program is installed.
Windows NT Server failover setup:
To install the IBM
Netfinity 10/100 Fault Tolerant Adapter device drivers:
1. Add the redundant NIC adapter according to the
instructions that are provided with the adapter.
2. Use the ServerGuide CDs to install the AMD PCNet
Ethernet Family adapter device driver.
3. Do not select the Grouping box at this point; you must
first restart the machine.
4. From the Windows NT Server desktop, select
Control
Panel
, then select the
Network
icon, then select the
Adapters
tab.
5. Highlight one of the adapters that will be in the
redundant pair and then click the
Properties...
button.
6. Check the Grouping box. This will show the possible
combinations for redundant pairs.
7. Select the adapter pair you want and then select
OK
.
Note that the integrated Ethernet controller is located at
PCI bus A, slot 2.
Two options are available for recovering from a failover
condition. The options are determined by the Enable
for DMI / Hot Swap Support checkbox. If the IBM
Netfinity Hot Plug PCI for Windows NT Server 4.0
package is installed, this checkbox will appear at the
bottom of the Adapter Properties panel. If you do not
have the IBM Netfinity Hot Plug PCI for Windows NT
Server 4.0 package installed on your server, you will
not see the Enable for DMI / Hot Swap Support
checkbox.
If the Enable for DMI / Hot Swap Support checkbox is
not checked or is not present, traffic will automatically
switch back to the primary adapter when the primary
108
: Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y,
41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Summary of Contents for Netfinity 5100 8658 21Y
Page 1: ...Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY S10K 2615 00...
Page 10: ...x Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 26: ...16 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 50: ...40 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 65: ...13 PCI slot 2 32 bit J32 Installing options 55...
Page 195: ...Parts listing Type 8658 Copyright IBM Corp 2000 185...
Page 196: ...186 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 215: ...Related service information 205...
Page 216: ...206 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 217: ...Related service information 207...
Page 218: ...208 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 219: ...Related service information 209...
Page 220: ...210 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 221: ...Related service information 211...
Page 222: ...212 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 235: ...Related service information 225...
Page 236: ...226 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 237: ...Related service information 227...
Page 245: ......
Page 246: ...Part Number 10K2615 Printed in U S A S10K 2615 00 1P P N 10K2615...