5
Filler panel
To install a hot-swap power supply:
1. Remove the filler panel from the empty power supply
bay by inserting your finger into the depression on the
filler panel and pulling it away from the server. Save
the filler panel in case you remove the power supply at
a later time.
Note:
During normal operation, each power-supply bay
must have either a power supply or filler panel
installed for proper cooling.
2. Install the power supply in the bay:
a. Place the handle on the power supply in the open
position (that is, perpendicular to the power supply)
and slide the power supply into the chassis.
b. Gently close the handle to seat the power supply in
the bay.
3. Plug the power cord for the added power supply into
the power cord connector.
4. Route the power cord through the cable-restraint
bracket.
5. Plug the power cord into a properly grounded electrical
outlet.
6. Verify that the DC Power light and AC Power light on
the power supply are lit, indicating that the power
supply is operating correctly.
7. If you have other options to install or remove, do so
now; otherwise, go to“Installing the cover” on page 92.
Removing a hot-swap power supply
Attention:
If you have not installed the power supply
backplane option, you have only one power supply, which
is not hot-swappable. To remove the single power supply,
or the only remaining hot-swap power supply, go to
“Removing the only power supply” on page 89. Otherwise,
continue with the following procedure.
To remove a hot-swap power supply:
1. If the NON LED on the diagnostic LED panel is lit, turn
off the server and peripheral devices; otherwise, go to
the next step.
2. Remove the power supply:
a. Unplug the power cord connector from the power
supply.
Attention:
Be careful when you remove the
hot-swap power supply; the power supply might be
too hot to handle comfortably.
88
: Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y,
41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Summary of Contents for Netfinity 5100 8658 21Y
Page 1: ...Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY S10K 2615 00...
Page 10: ...x Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 26: ...16 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 50: ...40 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 65: ...13 PCI slot 2 32 bit J32 Installing options 55...
Page 195: ...Parts listing Type 8658 Copyright IBM Corp 2000 185...
Page 196: ...186 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 215: ...Related service information 205...
Page 216: ...206 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 217: ...Related service information 207...
Page 218: ...208 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 219: ...Related service information 209...
Page 220: ...210 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 221: ...Related service information 211...
Page 222: ...212 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 235: ...Related service information 225...
Page 236: ...226 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 237: ...Related service information 227...
Page 245: ......
Page 246: ...Part Number 10K2615 Printed in U S A S10K 2615 00 1P P N 10K2615...