Voltage related system shutdown
Message
Action
System shutoff due to
x
current over
max value
(level-critical; system drawing
too much current on voltage
x
bus)
v
See “Power checkout” on page 31.
System shutoff due to
x
V over voltage
(level-critical; system shutoff due to
x
supply over voltage)
1.
Check the power-supply connectors
2. Power supply.
System shutoff due to
x
V under voltage
(level-critical system shutoff due to
x
supply
under voltage)
1.
Check the power-supply connectors.
2. Power supply.
System shutoff due to VRM x over
voltage
v
Replace VRM
x
.
System shutoff due to excessive (< 240
VA) loading
1.
See “Power checkout” on page 31.
2. Cycle ac on/off.
Temperature related system shutdown
Message
Action
System shutoff due to board over
temperature
(level-critical; board is over
temperature)
1.
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41.
2. Replace board.
System shutoff due to CPU x over
temperature
(level-critical; CPU
x
is over
temperature)
1.
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41.
2. Replace microprocessor
x
.
System shutoff due to CPU
x
under
temperature
(level-critical; CPU
x
is under
temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 4.
System shutoff due to DASD temperature
(sensor
x
)
(level-critical; DASD area
reported temperature outside recommended
operating range)
v
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41.
System shutoff due to high ambient
temperature
(level-critical; high ambient
temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 4.
System shutoff due to system board
under temperature
(level-critical; system
board is under temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 4.
DASD checkout
Message
Action
Hard drive
x
removal detected
(level-critical; hard drive
x
has been
removed)
v
Information only, take action as appropriate.
Symptom-to-FRU index
115
Summary of Contents for IntelliStation E Pro
Page 1: ...IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 2: ......
Page 3: ...IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 6: ...iv IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 10: ...viii IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 20: ...10 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 138: ...128 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 149: ...Related service information 139...
Page 150: ...140 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 151: ...Related service information 141...
Page 152: ...142 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 153: ...Related service information 143...
Page 154: ...144 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 155: ...Related service information 145...
Page 156: ...146 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 166: ...156 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 167: ...Related service information 157...
Page 168: ...158 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 169: ...Related service information 159...
Page 170: ...160 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 171: ...Related service information 161...
Page 172: ...162 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Page 181: ......
Page 182: ...Part Number 71P7605 1P P N 71P7605...