Inspect Electrical Parts
25
Customer Power Source Service Check
Use an ECOS Electrical Safety Tester (P/N 6339695) in the United States or a similar safety tester in other countries.
NOTE:
The ECOS tester will trip ground fault detector protected outlets. This is a good test of the ground fault detector. Reset
the outlet as needed.
Plug the ECOS meter into the customer’s outlet. Follow the instructions supplied with the meter to test for the following:
•
Wiring errors
•
Low voltage
•
Neutral to ground short
•
Ground path impedance
•
Neutral impedance
NOTE:
The customer is responsible for correcting problems with the power source.
Each branch circuit must be grounded for safety and correct operation of the printer. This ground must be connected either to
the electrical service ground or to a suitable building ground. The printer power cable has a green or green/yellow insulated
grounding conductor. This is a ground line,
not a neutral line.
Power Cable
1.
Make sure the power cable is not damaged.
2.
Make sure the power plug is the correct type.
Power On / Off Verification
1.
Make sure all covers are installed.
2.
Plug the power cable into the customer’s power outlet.
3.
Power on the printer and watch the LCD.
4.
Verify that the power-on diagnostic tests and initialization routines are successful.
5.
After successful initialization, the printer should cycle automatically to either the READY or NOT READY mode, depending
on which power on state was selected when the printer was configured.
6.
Power off the printer. Verify that the LCD goes completely blank and all fans stop.
Summary of Contents for Infoprint 6500-v05
Page 282: ...282 Cable Routing Cabinet Model...
Page 283: ...283 Cable Routing Pedestal Model...
Page 285: ...285 Cable Assembly Centronics Dataproducts Adapter 14H5522...
Page 286: ...286 Cable Assembly 5V Remote Power 14H5589 To Controller Board...
Page 292: ...292 Cable Assembly Card Cage Fan PIN 1 PIN 1 14H5285...
Page 294: ...294 Cable Assembly Exhaust Fan PIN 1 PIN 1 14H5286...
Page 298: ...298 Cable Assembly MPU PIN 1 PIN 3 PIN 2 PIN 1 14H5329...
Page 300: ...300 Cable Assembly Ribbon Motor Extension 63H7464...
Page 301: ...301 Cable Assembly Shuttle Motor Drive 14H5330 To Shuttle To Controller Board...
Page 302: ...302 Frame Cable Power Stacker 10R3912...
Page 303: ...303 Logic Cable Power Stacker 10R4590...
Page 304: ...304 Power Cable Power Stacker 57P1376 P1101 P1101...
Page 305: ...305 Vertical Rail Cable Power Stacker 10R3913...
Page 306: ...306 Elevator I O Cable Power Stacker 10R4053...
Page 307: ...307 Fan Assembly Hammer Bank P107 HBF P107 HBF 14H5159...
Page 308: ...308 Magnetic Pickup MPU Assembly 57G1476 P03...
Page 309: ...309 Switch Assembly Paper Detector Standard 14H5281 Black Back Forms Kit 02N7169...
Page 310: ...310 Switch Assembly Platen Interlock P107 PLO 14H5280...
Page 530: ...530 WR Write w With w o Without XMT Transmit...
Page 531: ...531...
Page 544: ...G544 5978 00 07G544597800 Copyright IBM Corp 2005...