Table
7.
Symptom-to-FRU
index
(continued)
Problem
indicator
Component
Possible
cause
Possible
solutions
Amber
LED
is
lit
(continued)
Front
panel
(Global
Summary
Fault
LED)
General
machine
fault
A
Fault
LED
is
lit
somewhere
on
the
storage
subsystem
(check
for
Amber
LEDs
on
CRUs).
General
machine
fault
(continued)
Open
the
DS4000
Storage
Manager
for
DR550
Storage
Subsystem
Management
window
and
click
on
the
Recovery
Guru
to
see
problems
in
the
DR550
Storage
Controller
configuration.
Some
errors
will
cause
the
Global
Summary
Fault
LED
to
be
lit
but
will
not
cause
any
individual
CRU
Fault
LEDs
to
be
lit.
(Drive
PFA
exceeded
or
nominal
temperature
exceeded
errors
are
a
few
examples.)
Follow
the
corrective
actions
in
the
Recovery
Guru
window.
Fibre
channel
connection
failure
Check
that
the
CRUs
are
properly
installed.
If
none
of
the
amber
LEDs
are
lit
on
any
of
the
CRUs,
this
indicates
an
SFP
module
transmission
fault
in
the
storage
subsystem.
Replace
the
failed
SFP
module.
See
the
DS4200
Installation,
User’s
and
Maintenance
Guide
for
more
information.
Battery
unit
fault
Battery
unit
failure
Verify
the
failure
using
DS4000
Storage
Manager
Client
and
replace
the
failing
battery.
Amber
LED
is
lit
and
green
LED
is
off.
Power
supply
CRU
The
power
switch
is
turned
off
or
there
is
an
AC
power
failure.
Replace
the
failed
power
supply
or
turn
on
all
power
supply
switches.
Amber
and
green
LEDs
are
lit.
Power
supply
CRU
Power
supply
failure
or
power
switch
is
turned
off
or
there
is
an
AC
power
failure.
Replace
the
failed
power
supply,
turn
on
all
power
supply
switches,
or
check
the
main
or
the
rack
power
unit
circuit
breaker.
All
amber
and
green
LEDs
are
slowly
flashing.
All
drive
CRUs
The
DR550
Storage
Controllers
are
going
through
start-of-day
process
(booting
up).
Wait
up
to
five
minutes
for
the
controllers
to
complete
the
booting
process.
If
the
drive
Activity
LEDs
are
not
steady
lit
or
momentarily
flicker,
and
the
amber
LEDs
are
unlit
after
waiting
more
than
six
minutes,
contact
IBM
support.
Chapter
6.
DR550
Storage
Controller
45
Summary of Contents for DR550
Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 2: ......
Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Printed in USA GA32 0576 00...