Concurrently
maintainable
battery
pack
:
Indicates
that
the
rechargeable
cache
battery
pack
can
be
replaced
while
the
adapter
continues
to
operate.
Battery
pack
can
be
safely
replaced
:
Indicates
that
the
adapter’s
write
cache
has
been
disabled
and
the
rechargeable
cache
battery
pack
can
be
safely
replaced.
Forcing
a
Rechargeable
Battery
Error
This
option
allows
you
to
force
your
PCI-X
SCSI
RAID
Controller
to
put
its
cache
battery
pack
into
an
error
state.
This
state
requires
replacement
of
the
battery.
Typically,
performing
this
task
ensures
that
write
caching
is
stopped
prior
to
replacing
a
cache
battery
pack.
Forcing
the
battery
error
will
result
in
the
following:
v
The
system
logs
an
error.
v
Data
caching
becomes
disabled
on
the
selected
controller.
v
System
performance
could
become
significantly
degraded
until
the
cache
battery
pack
is
replaced
on
the
selected
controller.
Ensure
that
you
have
the
correct
type
and
quantity
of
cache
battery
packs
to
do
the
replacement.
To
resume
normal
operations,
replace
the
cache
battery
pack.
The
cache
battery
pack
for
571F
storage
I/O
adapter
and
575B
Auxiliary
Cache
adapter
is
contained
in
a
single
battery
FRU
that
is
physically
located
on
the
575B
Auxiliary
Cache
adapter.
The
functions
of
forcing
a
battery
pack
error
and
starting
adapter
cache
on
either
adapter
in
the
card
set
will
result
in
the
same
function
automatically
being
performed
on
the
other
adapter
in
the
card
set.
To
force
the
battery
error,
do
the
following:
1.
Navigate
to
the
PCI-X
SCSI
Disk
Array
Manager.
2.
Select
Diagnostics
and
Recovery
Options
.
3.
Select
Controller
Rechargeable
Battery
Maintenance
.
4.
Select
Force
Controller
Rechargeable
Battery
Error
.
5.
Select
your
PCI-X
SCSI
RAID
Controller
whose
battery
you
want
to
replace.
Note:
Using
this
option
places
the
battery
into
the
error
state,
which
requires
it
to
be
replaced.
6.
Press
Enter
.
7.
Replace
the
cache
battery
pack
as
described
in
Replacing
the
rechargeable
cache
battery
pack
This
section
provides
instructions
for
replacing
the
rechargeable
cache
battery
pack.
Note:
When
replacing
the
cache
battery
pack,
the
battery
must
be
disconnected
for
at
least
60
seconds
before
connecting
the
new
battery.
This
is
the
minimum
amount
of
time
needed
for
the
card
to
recognize
that
the
battery
has
been
replaced.
Chapter
12.
Field
replacement
97
Summary of Contents for DR550
Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 2: ......
Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Printed in USA GA32 0576 00...