the
directory
structure
tree
can
be
expanded
to
find
/tmp/ibmsupt
.
This
snap
file
can
then
be
e-mailed
to
the
IBM
support
center
for
analysis.
g.
To
gather
problem
data
for
the
DR550
File
System
Gateway,
use
the
following
diagnostic
tools,
described
in
greater
detail
in
v
POST
beep
codes
v
v
Diagnostic
programs
and
error
messages
v
Light
path
diagnostics
h.
To
gather
problem
data
for
the
DR550
Storage
Controller:
v
Check
the
Storage
Controller,
Expansion
Drawers
and
disk
drives
to
see
if
any
amber
LEDs
are
lit
for
first
problem
determination.
v
Use
the
Recovery
Guru
menu
function
in
the
DS4000
Storage
Manager
for
DR550
Subsystem
Management
window
to
identify
and
correct
any
failures.
v
Look
at
the
DS4000
Storage
Manager
Major
Event
Log
(MEL)
and
gather
all
support
data.
v
Click
Downloads
>
Advanced
Option
>
Maint
.
Select
Collect
All
Support
Data
.
3.
Establish
a
history
of
the
problem;
request
the
following
information:
a.
How
did
you
first
notice
the
problem?
Did
the
user
do
anything
different
that
made
them
notice
the
problem?
b.
When
did
it
happen?
Does
it
always
happen
at
the
same
time,
for
example
when
the
same
application
is
run
or
a
specific
user
accesses
the
system.
c.
Does
the
same
problem
occur
elsewhere?
Is
only
one
machine
experiencing
the
problem
or
are
multiple
machines
experiencing
the
same
problem?
d.
Have
any
hardware,
software,
or
configuration
changes
been
made
recently?
e.
If
a
change
has
been
made
recently,
were
all
required
prerequisites
met
before
the
change
was
made?
4.
Gather
information
from
the
system.
Use
the
following
worksheet
as
a
guide.
Questions
Responses
1.
Problem
Definition
2.
Time/Date
of
Failure
3.
How
was
the
problem
detected?
Does
the
problem
existing
on
multiple
machines?
Was
the
error
detected
by
a
user?
Was
the
error
detected
by
the
system?
Which
management
interface
exhibited
the
problem?
For
example,
with
the
DR550
SSAM
Server,
was
it
SMIT
or
CLI?
4.
Are
any
error
LEDs
lit?
If
yes,
which
hardware
product?
5.
Is
there
a
service
request
number
displayed
on
the
SSAM
Server?
6.
For
AIX
error
messages,
is
the
message
prefix,
ANR,
ANS,
or
ANE.
If
yes,
the
message
was
generated
by
System
Storage
Archive
Manager.
Chapter
1.
Problem
resolution
overview
3
Summary of Contents for DR550
Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 2: ......
Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Printed in USA GA32 0576 00...