The SRNs
SRN
FRU List
Problem
10104
None
Description: Format in progress.
Action: Wait for the formatting operation to end, then run
concurrent diagnostics to ensure that no more problems
exist. For information about how to run concurrent
diagnostics, see Concurrent Diagnostics in the “Additional
Information” appendix (in this book) for your using system.
10112
None
Description: Format degraded. A Format operation has been
ended before it has completed.
Action: Use the Format service aid to format the disk drive
module.
1022F
Disk-drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: Critical over-temperature has been detected.
Action: A disk drive module has reported that the
temperature is too high.
v
If the ambient temperature is too high, take actions to
decrease it.
v
If the ambient temperature is within specification,
exchange the FRU for a new FRU.
1XXXX
Disk-drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: Disk drive module error.
Action: Exchange the FRU for a new FRU (see “Physical
Location of a Device” on page 59).
Note: In this SRN, an X represents a digit 0 through F.
20PAA
Disk-drive module (45%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
SSA attachment (45%) (using-system
Installation and Service Guide).
External SSA cables, optical
extenders, or main fibre optic cables
(6%).
Frame assembly (2%) (“Frame
Assembly” on page 208).
Bypass card (2%) (“Bypass (SNBC)
Cards” on page 201).
Description: An open SSA loop has been detected.
Action: Run a link verification, or physical view, service aid
to isolate the failure (see the user or maintenance
information for your using-system SSA attachment).
If the SSA service aids are not available:
v
When the failing device is in a 7133 Model D40 or Model
T40, go to step 12 on page 90 in MAP 2010: 7133
Models D40 and T40 – START.
v
When the failing device is not in a 7133 Model D40 or
Model T40, go to the service information for that device.
Chapter 2. Problem Determination Procedures
77
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...