Table 1. Error IDs and Their Related SRNs
Error ID
See SRN
BP1
BP16
80241
80242
BP4
BP5
80243
80244
BP8
BP9
80245
80246
BP12
BP13
80247
80248
CODE
80210
COLD
80253
COOL
80254
CTRL
80210
FAN1
80231
FAN2
80232
FAN3
80233
HOT
80251
OPNL
80211
POST-FAIL-XXXX
Where XXXX=
XROM WDOG IROM
IRAM LED! I2C
RTC1 RTC2 TIME
UART FAN XRAM
80210
PSU1
80221
PSU2
80222
SLOT
80260
WARM
80252
Note: If the COLD or HOT error ID remains for four minutes, the internal dc power
switches off (that is, the 7133 enters Standby mode).
If the error ID is COLD, the internal dc power switches on automatically after the
temperature has increased and has remained more than 5°C above the critical
temperature for 15 minutes.
If the error ID is WARM, the error is not reset until the ambient temperature has
fallen at least 2°C below the warning level.
If the error ID is HOT, the internal dc power switches on automatically after the
temperature has decreased and has remained more than 5°C below the critical
temperature for 15 minutes.
10
7133 Models D40 and T40 Service Guide
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...