6. Refer to Figure 41.
7. If the 7133 has a Remote Power On Control feature, ensure that no using system
power-control cables are present at the MAIN and AUX connectors
1
.
8. Check for continuity between the frame of the 7133 (
6
and the ground pin of each power cable.
9. If the continuity is good, the grounding of the 7133 is correct. Go no further with
these instructions.
10. If the grounding is not correct, unplug the power cables from the mainline power
connectors at the top of the 7133. Then continue with step 11.
1
Figure 41. Remote-Power-On Control Unit