Grounding Check (Model T40)
1. Refer to Figure 40.
2. At the back of the 7133, ensure that the short cables
3
and
4
are plugged into
the power supply assemblies, and that a power cable is plugged into each of the
power sockets
1
and
2
.
3. Ensure that the other ends of the power cables are not plugged into electrical
power outlets. Unplug the cables if necessary.
4. Attention: Some electrical circuits could be damaged if the external SSA cables or
power control cables are present at the 7133 while the grounding check is being
done.
Ensure that no external SSA cables are present at the eight connectors
5
.
5. If the 7133 has a Remote Power On Control feature, go to step 6 on page 70.
Otherwise, go to step 8 on page 70.
5
5
1
2
3
4
6
Figure 40. Power Cables and SSA Sockets (Model T40)
Chapter 1. Reference Information
69
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...