SRN
FRU List
Problem
80254
None
Description: Under-Temperature Warning level has been
exceeded.
Action: Take actions to increase the ambient temperature.
80260
None
Description: An empty disk drive module slot has been
reported. The slot has been empty for longer than one
minute.
Action: Use the service functions (see “Service Functions”
on page 62) to find the slot that has been reported empty.
80280
None
Description: A disk drive module cannot be configured for
some unknown reason.
Action: Go to “MAP 2010: 7133 Models D40 and T40 –
START” on page 87. If no problem is found, go to Software
and Microcode Errors in the “Additional Information”
appendix (in this book) for your using system.
80290
Controller card asm (97%) (“Controller
Card Assembly” on page 199).
None (3%)
Description: A function has failed because access to the
7133 controller is not possible. This problem might be
caused by system activity.
Action: Check whether you can get access to the disk drives
of the 7133:
v
If you can get access, run the failing function again. If the
same SRN is generated, exchange the FRU for a new
FRU.
v
If you cannot get access, solve the problem that prevents
access to the disk drives, the run the failing function
again.
D0000
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The using system cannot configure the disk
drive module.
Action: This is probably a software problem. Try again to
configure the disk drive module.
If the problem remains, go to Software and Microcode
Errors in the “Additional Information” appendix (in this book)
for your using system before exchanging the FRU.
D0100
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: Unable to clear a disk drive module reservation.
Action: Exchange the FRU for a new FRU.
D0101
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The disk drive module has been reserved since
the diagnostics started.
Action: The disk drive module is in use. Release the disk
drive module, and run the diagnostics again.
Chapter 2. Problem Determination Procedures
83
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...