SRN
FRU List
Problem
8023X
Fan assembly (95%) (“Fan Assemblies”
Controller card asm (3%) (“Controller
Card Assembly” on page 199).
Frame assembly (2%) (“Frame
Assembly” on page 208).
Description: The fan assembly in position X has failed.
v
80231 means the fan assembly in position 1.
v
80232 means the fan assembly in position 2.
v
80233 means the fan assembly in position 3.
Action: Exchange the FRUs for new FRUs.
8024X
Bypass card (95%) (“Bypass (SNBC)
Cards” on page 201).
Controller card asm (3%) (“Controller
Card Assembly” on page 199).
Frame assembly (2%) (“Frame
Assembly” on page 208).
Description: Bypass card SSA port X has failed.
v
80241 means SSA port 1.
v
80242 means SSA port 16.
v
80243 means SSA port 4.
v
80244 means SSA port 5.
v
80245 means SSA port 8.
v
80246 means SSA port 9.
v
80247 means SSA port 12.
v
80248 means SSA port 13.
Action: Exchange the FRU for a new FRU.
80251
None
Description: Critical Over-Temperature has been detected.
Action: Take actions to decrease the ambient temperature. If
you are working on a 7133 Model D40, ensure that the
requirements for good airflow have been met. For details,
see the Notes under “Environment” on page 38.
Note: If this error causes the internal dc power of the 7133
to switch off (that is, the 7133 enters Standby mode), the
internal dc power switches on automatically after the
temperature has decreased and has remained more than
5°C below the critical temperature for 15 minutes.
80252
None
Description: Over-Temperature Warning level has been
exceeded.
Action: Take actions to decrease the ambient temperature. If
you are working on a 7133 Model D40, ensure that the
requirements for good airflow have been met. For details,
see the Notes under “Environment” on page 38.
Note: If the error ID is WARM, the error is not reset until
the ambient temperature has fallen at least 2°C below the
warning level.
80253
None
Description: Critical Under-Temperature has been detected.
Action: Take actions to increase the ambient temperature.
Note: If this error causes the internal dc power of the 7133
to switch off (that is, the 7133 enters Standby mode), the
internal dc power switches on automatically after the
temperature has increased and has remained more than
5°C above the critical temperature for 15 minutes.
82
7133 Models D40 and T40 Service Guide
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...