Enclosure Environment Information
For a selected 7133 Model D40 or Model T40, the service aids display the status of:
v
Power supply assemblies
v
Fan assemblies
v
Operator panel
v
Remote-Power-On control unit
v
Controller card assembly
v
Ambient temperature
Change Enclosure Settings Information
For a selected 7133 Model D40 or Model T40, the service aids allow you to change the
following settings:
v
Enclosure ID.
v
Bypass card mode (Automatic, Forced Inline, Forced Bypass, and Forced Open).
v
Temperature warning levels (low and high).
You can also reset the Exchanged and Swap flags for the FRU.
Note: The Exchanged and Swap flags show whether a FRU has been removed or
exchanged since its flag was last reset. These flags are especially useful if you
are trying to solve an intermittent problem that might be caused by more than
one FRU.
Chapter 1. Reference Information
63
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Page 10: ...viii 7133 Models D40 and T40 Service Guide ...
Page 14: ...xii 7133 Models D40 and T40 Service Guide ...
Page 90: ...72 7133 Models D40 and T40 Service Guide ...
Page 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Page 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Page 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Page 292: ...274 7133 Models D40 and T40 Service Guide ...
Page 305: ......
Page 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...