Chapter 5 List of Parameters
5.1 I/O Parameters
167
I/O Parameters
No.
Parameter name
Default
value
(Reference)
Input range
Unit
Remarks
225 Extension I/O control
Common
0H
0H ~
FFFFFFFFH
Bits 0 to 3:
I/O2 Module Type
Bits 4 to 7:
I/O3 Module Type
(0: Not mounted
1: I CC-Link,
2: DeviceNet,
3: PROFIBUS,
4: IA-NET
(It is applicable for main application part V1.17 and
later of the pulse motor type and from the first lot of
the AC servomotor type)
5: System reservation,
6: EtherCAT,
(It is applicable for main application part V1.17 and
later of the pulse motor type and from the first lot of
the AC servomotor type)
7: EtherNet/IP,
8: System reservation
9: PIO)
A: PROFINET IO
(It is applicable for main application part V1.17 and
later of the pulse motor type and from the first lot of
the AC servomotor type)
B: System reservation,
C: Extension SIO
* EtherNet/IP, IA-NET, PROFINET IO is
unavailable for 2-piece mount at same time
226 I/O2 fieldbus node
address
Common
0
0 ~ 99999999
•
When CC-Link: 1 to 64
•
When DeviceNet: 0 to 63
•
When PROFIBUS: 0 to 125
•
When EtherCAT: 0 to 65535
227 I/O2 fieldbus
communication speed
Common
0
0 ~ 9
•
When CC-Link:
(0: 156kbps, 1: 625kbps, 2: 2.5Mbps, 3: 5Mbps, 4: 10Mbps)
•
When DeviceNet:
(0: 125kbps, 1: 250kbps, 2: 500kbps, 3: Auto)
•
When EtherNet/IP:
(0: Auto negotiation, 1: 10Mbps (Half-duplex), 2: 10Mbps
(Full-duplux), 3: 100Mbps (Half-duplex), 4: 100Mbps
(Full-duplux))
* Setting unnecessary when PROFIBUS
Setting unnecessary when EtherCAT
228 (For extention)
Common
0
229 (For extention)
Common
0
230 (For extention)
Common
0
231 Number of I/O3 fieldbus
remote input used ports
Common
0
0 ~ 240
Multiple of 8
232 Number of I/O3 fieldbus
remote output used ports Common
0
0 ~ 240
Multiple of 8
233 Input port start number at
I/O3 affixed assignment
Common
-1
-1 ~ 299
0 + (Multiple of 8) (Invalid if a negative value is set)
234
Output port start number
at I/O3 affixed
assignment
Common
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
235 I/O3 error monitor
Common
1
0 ~ 5
0: Do not monitor
1: Monitor
* Some exceptions apply.
236 (For extention)
Common
0
237 I/O3 fieldbus node
address
Common
0
0 ~ 99999999
•
When CC-Link: 1 to 64
•
When DeviceNet: 0 to 63
•
When PROFIBUS: 0 to 125
•
When EtherCAT: 0 to 65535
238 I/O3 fieldbus
communication speed
Common
0
0 ~ 9
•
When CC-Link:
(0: 156kbps, 1: 625kbps, 2: 2.5Mbps, 3: 5Mbps, 4: 10Mbps)
•
When DeviceNet:
(0: 125kbps, 1: 250kbps, 2: 500kbps, 3: Auto)
•
When EtherNet/IP:
(0: Auto negotiation, 1: 10Mbps (Half-duplex), 2: 10Mbps
(Full-duplux), 3: 100Mbps (Half-duplex), 4: 100Mbps
(Full-duplux))
* Setting unnecessary when PROFIBUS
Setting unnecessary when EtherCAT
239 (For extention)
Common
0
240 (For extention)
Common
0
241 (For extention)
Common
0
242 (For extention)
Common
0
243 (For extention)
Common
0
Summary of Contents for TTA Series
Page 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Page 2: ......
Page 4: ......
Page 23: ...13 ...
Page 24: ...14 ...
Page 25: ...15 ...
Page 42: ...32 ...
Page 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Page 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Page 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Page 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Page 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Page 370: ...Chapter 10 Life 360 ...
Page 377: ......