Operating and Maintenance Instruction FCU 8000-1 series
Doc.: 3109776 Ed.: 01/13.02.2002
HYDAC Filtertechnik GmbH
E
Page 86
5.5.5.3 Programmable relay limit switches
FCU 8110 :
min
Max
M2 switching limits
2 µm channel NAS
1
15
5 µm channel NAS
1
15
15 µm channel NAS
1
15
25 µm channel NAS
1
15
50 µm channel NAS
1
15
100 µm channel NAS 1
15
2 µm channel ISO
10
25
5 µm channel ISO
7
23
15 µm channel ISO
5
21
Flow rate
0
150
M3 filtration limit
ISO
10 / 7 / 5
25 / 23 / 21
NAS
1 / 1 / 1
15 / 15 / 15
M4 filtration limits
ISO
10 / 7 / 5
25 / 23 / 21
NAS
1 / 1 / 1
15 / 15 / 15
Test cycle time
0
1440
FCU 8210 :
min
Max
M2 switching limits
4 µm
(c)
channel ISO
10
25
6 µm
(c)
channel ISO
7
23
14 µm
(c)
channel ISO 5
21
Flow rate
0
150
M3 filtration limit
ISO
10 / 7 / 5
25 / 23 / 21
M4 filtration limits
ISO
10 / 7 / 5
25 / 23 / 21
Test cycle time
0