IGNITION SYSTEM 21
Stator winding - check the short circuit to ground {terminal 31)
Measure the resistance between the specified points.
Alternator, connector
CR
pin
1
- Measuring point
Ground
{-)
I
Resistance
I
00
n
21.5
21.6
If the displayed value does meet specifications:
Change the stator.
Removing the stator
D00343-10
Installing the stator
Condition
The alternator cover has been removed.
Remove screws
O.
Remove the retaining bracket.
Remove screws
8.
Remove rubber grommet
@)
from the alternator cover.
Remove the stator from the alternator cover.
Position the stator in the alternator cover.
Mount and tighten screws
O.
Guideline
..
Screw, stator
0
M5
6 Nm (4.4 lbf ft)
Loctite
®
243
™
D00343-11
Position the retaining bracket.
Mount and tighten screws
8.
Guideline
Crankshaft
M5
speed sen-
sor screw and
cable retainer
6 Nm (4.4 lbf ft)
Loctite
®
243
™
Position rubber grommet
@)
in the alternator cover.
..
261