Installation Manual – BTS3606A Cabinet Installation
Airbridge BTS3606&3606A CDMA Base Station
Chapter 4 Installing Outdoor Transmission and
Power Interface Boxes
Huawei Technologies Proprietary
4-4
Figure 4-4
Default configuration of PSI power interface box
4.2 Installing Outdoor Transmission and Power Interface Box
Caution:
When installing the transmission interface box, the length of the cable between the box
and BTS3606A cabinet must be less than 7 m (240 in.).
Since TSI-DDF/ODF transmission interface box and PSI power interface box are
outdoor equipment, their enclosures can be mounted on wall or on steel pole as
needed.
The following respectively introduces how to mount the transmission interface box on
the wall and on the steel pole.
4.2.1 Mounting Transmission Interface Box on the Wall
Note:
Use the M8 expansion bolts to fasten the transmission interface box and the
percussion drill with a
φ
10 drill bit to drill holes.
To install the transmission interface box on the wall, proceed as follows:
1)
Position the transmission interface box according to the project requirement.
2)
Stick the lineate paper template delivered with the box to the wall.
3)
Mark installation holes of the four expansion bolts on the wall surface, as shown in
Figure 4-5.