background image

I/O Expansion by using the OCTA-CAPTURE with the VS-100/VS-700

Summary of Contents for Octa-Capture

Page 1: ...I O Expansion by using the OCTA CAPTURE with theVS 100 VS 700 ...

Page 2: ...obtain a coaxial cable separately This setup cannot be used at 192 kHz or higher An internal hard disk drive that s 7200 rpm or faster is required In order to use this setup at 96 kHz or higher a separate SATA hard disk drive is required as the audio recording destination This setup will not work with a USB hard disk Depending on the application you re using the operating requirements may exceed t...

Page 3: ...stem software version will appear USB updater 0 V1 30 01CA current version 2 Use the USB cable to connect the VS 100 to your computer When the USB connection is detected the following screen will appear USB updater 0 USB Online V1 30 01CA 3 Double click UpdSMFJ on your computer 4 In the MIDI Out Device field choose CONTROL VS 100 on a Mac choose CONTROL 5 Click the Path button on a Mac the Select ...

Page 4: ...rsion of theVS 700C console Check the version of the VS 700C console VS 700 I O CPU VS 700 I O DSP and VS 700 I O FANTOM VS If the version number is 1 30 or later the update is not required 1 Switch off the VS 700C s power 2 On the rear panel set switch 8 of the SETTING switches to the ON position upward this selects Update mode Normal setting Update mode 3 Switch on the VS 700C s power 4 The vers...

Page 5: ...e VS 700R I O CPU and DSP simultaneously in a single operation 1 Disconnect all USB cables from your computer except those connecting the keyboard and mouse 2 Make sure that the VS 700R s power is switched off 3 Disconnect everything from the VS 700R except for the power cord 4 In the VS 700R s top panel remove the expansion board cover then at the right side turn SW1 4 on and turn the other switc...

Page 6: ...puter double click UpdSMFJ 13 As the MIDI Out Device choose FANTOM VS VS 700 for Mac OS FANTOM VS 14 Click the Path button for Mac OS the Select button and in the SMF Path for Mac OS the SMF Folder indication specify the location of the update file FantomVSUpdate mid 15 Click the Scan SMF button not necessary on Mac OS and verify that the update file FantomVSUpdate mid is shown in the file list 16...

Page 7: ...9 7 7 DIGITAL AUTO SAMPLE FREQ Same settings as the OCTA CAPTURE VS EXPAND ON 8 6 1 2 Connecting theVS 700 and the OCTA CAPTURE You ll be able to use the OCTA CAPTURE and VS 700 as a 29 in 34 out of these 2 IN 2 OUT are used for synchronization audio interface with ASIO on Windows or with Core Audio on Mac OS X In order to connect two the VS 700 and OCTA CAPTURE you must turn on the VS EXPAND sett...

Page 8: ...es not match Alternatively you can ensure that the VS 100 VS 700 and the OCTA CAPTURE are connected to the same USB controller by connecting them both to a USB 2 0 compliant hub If Sampling frequency does not match is shown Disconnect both USB cables from the computer turn off the power of the first unit and start again from step 4 Connect each OCTA CAPTURE unit to the same USB controller If VS EX...

Page 9: ...TA CAPTURE will be output from the PHONES jack of the VS 100 VS 700 For theVS 700 Using VS 700 I O Editor or the VS 700 Control Surface plug in set DIGITAL1 INPUT SOURCE to COAXIAL IN and set SYNC SOURCE to DIGITAL1 For details refer to the online manual Setting the sampling frequency 1 Disconnect the coaxial cable that connects the VS 100 VS 700 and the OCTA CAPTURE units 2 Disconnect the two USB...

Page 10: ...VS VS 700 VS 700 MAIN VS 700 ARX VS 700 SUB VS 700 AUX VS 700 1 2 VS 700 1 2 VS 700 3 4 VS 700 3 4 VS 700 5 6 VS 700 5 6 VS 700 7 8 VS 700 7 8 VS 700 9 10 VS 700 DIGITAL1 VS 700 DIGITAL1 VS 700 DIGITAL2 1 2 VS 700 DIGITAL2 1 2 VS 700 DIGITAL2 3 4 VS 700 DIGITAL2 3 4 VS 700 DIGITAL2 5 6 VS 700 DIGITAL2 5 6 VS 700 DIGITAL2 7 8 VS 700 DIGITAL2 7 8 VS 700 OCTA CAPTURE Input Device Output Device OCTA C...

Page 11: ... EXP OUT 9 10 EXP MAIN Core Audio device ports and input channel numbers Device Port Core Audio channel number VS 100 IN 1 2 1 2 IN 3 4 3 4 IN 5 6 5 6 DIGITAL 7 8 MAIN 9 10 OCTA CAPTURE VS Expand ON IN 1 2 11 12 IN 3 4 13 14 IN 5 6 15 16 IN 7 8 17 18 IN 9 10 19 20 MAIN 21 22 Core Audio device ports and output channel numbers Device Port Core Audio channel number VS 100 OUT 1 2 1 2 OUT 3 4 3 4 OUT ...

Page 12: ... 2 DIGITAL2 3 4 DIGITAL2 5 6 DIGITAL2 7 8 OCTA CAPTURE VS Expand ON EXP IN 1 2 EXP IN 3 4 EXP IN 5 6 EXP IN 7 8 EXP IN 9 10 EXP MAIN ASIO output port names Device Port 44 1 48 kHz 96 kHz VS 700 MAIN SUB OUT 1 2 OUT 3 4 OUT 5 6 OUT 7 8 OUT 9 10 DIGITAL1 DIGITAL2 1 2 DIGITAL2 3 4 DIGITAL2 5 6 DIGITAL2 7 8 OCTA CAPTURE VS Expand ON EXP OUT 1 2 EXP OUT 3 4 EXP OUT 5 6 EXP OUT 7 8 EXP OUT 9 10 ...

Page 13: ...N 1 2 25 26 21 22 IN 3 4 27 28 23 24 IN 5 6 29 30 25 26 IN 7 8 31 32 27 28 IN 9 10 33 34 29 30 MAIN 35 36 31 32 Core Audio device ports and output channel numbers Device Port Core Audio channel number 44 1 48 kHz 96 kHz VS 700 MAIN 1 2 1 2 SUB 3 4 3 4 OUT 1 2 5 6 5 6 OUT 3 4 7 8 7 8 OUT 5 6 9 10 9 10 OUT 7 8 11 12 11 12 OUT 9 10 13 14 13 14 DIGITAL1 15 16 15 16 DIGITAL2 1 2 17 18 17 18 DIGITAL2 3 ...

Page 14: ...ettings from the OCTA CAPTURE s control panel When updating the VS 700 s system program the input indicator blinked when you connected the USB cable to your computer and the update could not be performed After powering up the VS 700 did you return the SW1 4 switch to the off position You performed the VS 700C console update as directed by the manual but it was not successful Could a device other t...

Reviews: