80 Chapter 6 Operating the press
ENWW
2
The
Last Machine LUT Validation Results
window shows the last Job LUT validation
performed.
Calibrating the inline densitometer
The inline densitometer is the heart of the press color management. Calibrate the
densitometer to ensure correct readings.
1
On the
Adjustments
menu, click
Color Adjustment and Calibration
. The Color
Adjustment and Calibration Wizard Manager opens.
2
In the
Inline Densitometer Calibration
section, click
Quick
. The Quick Densitometer
Calibration Wizard opens.
3
Press F1, the online help opens.
Figure 6-33.
Last Machine LUT Validation Results
window
Figure 6-34. Color Adjustment and Calibration Wizard Manager
The number of impressions
performed since the last validation
Date and time for
the last validation
The laser power, developer
voltage, and solid optical density
at the time of the validation
The results of the last
machine LUT generation
Summary of Contents for Indigo press 3050
Page 1: ...HP Indigo press 3050 User guide English version ...
Page 2: ...hp indigo press 3050 user guide ...
Page 13: ...12 Chapter 1 Preface ENWW ...
Page 23: ...22 Chapter 2 Getting started ENWW ...
Page 41: ...40 Chapter 4 HP Indigo press 3050 basics ENWW Figure 4 5 Related topics ...
Page 53: ...52 Chapter 5 The main windows ENWW ...
Page 83: ...82 Chapter 6 Operating the press ENWW ...
Page 91: ...90 Chapter 7 Operator routines ENWW Figure 7 7 Inner front wall O O O O ...
Page 99: ...98 Chapter 7 Operator routines ENWW ...
Page 136: ...ENWW 135 10PIP This chapter contains the following sections z Overview z Replacing the PIP ...
Page 189: ...188 Chapter 11 Paper transport ENWW ...
Page 219: ...218 Chapter 15 Scorotron ENWW ...
Page 257: ...256 Chapter 17 Pre transfer erase PTE ENWW ...
Page 271: ...270 Chapter 19 Chiller ENWW ...