Technical Specification
Feature
Power consumption*:
Power Rating
ISR 9024S — 51W, max.
ISR 9024S-M — 63W, max.
ISR 9024D — 58W, max.
ISR 9024D-M — 69W, max.
BTU/hour = Watts x 3.413
90 Vac/60 Hz/Max Load = 0.998
Power Factor:
120 Vac/60 Hz/Max Load = 0.997
230 Vac/60 Hz/Max Load = 0.973
264 Vac/60 Hz/Max Load = 0.957
120W
Maximum Power Draw
82%
Power Supply Efficiency
0.737 [mA]
Leakage current @ 264V
2 power cords, 2 meter jumper, with a universal plug for PDU (Power Distribution Unit).
Acoustic Data
ISR Noise power is 6.5db.
Physical Characteristics
1.69" (43 mm) x 16.929" (430 mm) x 20.59" (523 mm)
Dimensions (H x W x D)
19” (482.6 mm), with optional front or rear rack mounting
Rack column width
17 lb (7.7 kg), excluding rack mounting
Weight
Reliability
over 160,000 hours
Internally managed
over 200,000 hours
Externally managed
Environmental Operating
32°F to 113°F (0°C to 45°C)
Temperature
15% to 80%, non-condensing
Humidity
0 to 9843 ft (3000m)
Altitude
Environmental Storage
–13°F to 185°F (-25°C to +85°C)
Temperature
5% to 90% non-condensing
Humidity
0 ft to 15,000 ft (4570 m)
Altitude
Maximum Ambient Temperature
45°C
Certifications of Compliance
cULus (USA-E17018/CAN-ICES/NMB-003 Class/Classe A)
Safety
CE according EN 60950-1 First Ed.
CB according IEC 60950-1 First Ed.
114
ISR 9024 S/D Interconnect Specifications (RoHS Compliant)
Summary of Contents for Cluster Platform Express v2010
Page 10: ...10 ...
Page 18: ...18 ...
Page 28: ...28 ...
Page 38: ...38 ...
Page 68: ...68 ...
Page 92: ...92 ...
Page 106: ...106 ...
Page 110: ...110 ...
Page 116: ...116 ...
Page 122: ...122 ...
Page 124: ...124 ...
Page 132: ...132 ...