1-29
Company confidential. Murillo/Ravillo User’s Guide. Final Freeze Status: Frozen
This is the cyan on page 1-29 (seq: 47)
This is the black on page 1-29 (seq: 47)
Task 8: Configure the Interface (Serial Interface Users
Only)
The following table shows the settings available for the plotter’s serial interface
parameters, the factory defaults and the most likely requirements for different
computers.
Serial (RS-232-C) Settings
Likely requirement for ...
Available
Likely requirement for ...
Parameter
Available
settings
PC
Macintosh
Unix
Baud rate
1200
2400
4800
9600
19200
38400
9600
(2)
9600
Parity
(1)
None
Even
Odd
None
(2)
None
Italics = factory default
(1)
Parity of None = 8 data bits, 1 stop bit
Parity of Even or Odd = 7 data bits, 1 stop bit
(2)
Consult your software documentation.
The settings on the plotter must match those of the computer and software sending
the data. Use their documentation to find the requirements. If in doubt, try with
the above suggestions. If the plotter’s defaults already match the requirements,
then you can skip the rest of this task.
SETUP
1
Setting Up the Plotter
Task 8: (Serial Interface Users Only) Configure the Interface