aurora
Tempo
- User Guide
4-14
423972
Specifying the length of the test
•
Highlight
Duration
and press the RIGHT arrow key to
display a sub-menu.
•
Enter the length of the test in seconds. Enter 0 to
perform a continuous BER test. Press ENTER to save
this value and exit the sub-menu.
Setting the resynchronization level
You can set the threshold at which aurora
Tempo
will
automatically resynchronize to the received Bert pattern.
This threshold is expressed as a percentage of errors within a
100 millisecond time period.
•
Choose
Sync. threshold
to display a sub-menu and
select the appropriate percentage of errors.
Specifying a pass/fail measure
You can set the criterion which establishes whether a BER
Test passes or fails. To do this :
•
Select
Pass Measure
to display a sub-menu of different
measures.
•
Choose the measure which will be used to determine if
the BER Test passes or fails.
Setting a BERT pass threshold
In addition to setting a pass/fail measure, you can also set a
pass/fail threshold for a BER Test :
•
Select
Pass-threshold
to display a sub-menu of
thresholds.
•
Choose the appropriate threshold. For example, select
1 in 10ˆ2
to set the threshold as 1 in 10
2
bits.
Summary of Contents for auroraTempo
Page 2: ...423972 Issue 1a 10 99 auroraTempo User Guide ...
Page 26: ...auroraTempo User Guide 1 16 423972 ...
Page 35: ...Issue 1a 10 99 3 3 Getting Started Connecting auroraTempo within the Frame Relay Network ...
Page 48: ...auroraTempo User Guide 3 16 423972 ...
Page 56: ...auroraTempo User Guide 4 8 423972 The following table provides a key to the T1 display ...
Page 80: ...auroraTempo User Guide 4 32 423972 ...
Page 110: ...auroraTempo User Guide 5 30 423972 ...
Page 178: ...auroraTempo User Guide 5 98 423972 ...
Page 197: ...Issue 1a 10 99 6 19 Configuring auroraTempo ...
Page 198: ...auroraTempo User Guide 6 20 423972 ...
Page 202: ...auroraTempo User Guide 6 24 423972 ...
Page 214: ...auroraTempo User Guide 7 12 423972 ...
Page 236: ...auroraTempo User Guide 8 22 423972 ...
Page 242: ...auroraTempo User Guide A1 6 423972 34 Way MRAC Winchester Connector Male Part number 423355 ...
Page 252: ...auroraTempo User Guide A1 16 423972 ...
Page 262: ...auroraTempo User Guide A3 2 423972 Appendix 3 Menutrees Main Menu Menutree ...
Page 265: ...Issue 1a 10 99 A3 5 Appendix 3 Menutrees Setup Config Menutree ...
Page 266: ...auroraTempo User Guide A3 6 423972 ...
Page 267: ...Issue 1a 10 99 A4 1 Appendix 4 Glossary Appendix 4 Contents Glossary A4 2 ...
Page 280: ...auroraTempo User Guide A4 14 423972 ...
Page 284: ...auroraTempo User Guide A5 4 423972 ...
Page 285: ...Issue 1a 10 99 Index 1 Index ...