![HP auroraTempo User Manual Download Page 128](http://html.mh-extra.com/html/hp/auroratempo/auroratempo_user-manual_161541128.webp)
aurora
Tempo
- User Guide
5-48
423972
This window displays the following information:
Total Frames
Frame Rate
Max Frm Size
Min Frm Size
Total Octets
Bit Rate
BECN Frames
FECN Frames
DE Frames
Short Frames
This is the total number of frames either transmitted or
received for the chosen DLCI since the start or reset of
statistics collection.
This is the total number of frames either transmitted or
received per second - in other words, the throughput of
frames within one second.
Maximum Frame size - this is the maximum frame size either
transmitted or received for the chosen DLCI since the start
or reset of statistics collection.
Minimum Frame Size - this is the minimum frame size either
transmitted or received for the chosen DLCI since the start
or reset of statistics collection.
This is the total number of octets either transmitted or
received for the chosen DLCI since the start or reset of
statistics collection.
This is the number of bits either transmitted or received
per second - in other words, the throughput of bits
within one second.
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Backward Explicit Congestion Notification (BECN) bits set.
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Forward Explicit Congestion Notification (FECN) bits set.
This is the number of frames either transmitted or received
over the virtual circuit for the chosen DLCI which have
Discard Eligible (DE) bits set.
This is the number of frames either transmitted or received
for the chosen DLCI whose length falls short of the specified
number of bytes.
Statistics
Display
Description
Summary of Contents for auroraTempo
Page 2: ...423972 Issue 1a 10 99 auroraTempo User Guide ...
Page 26: ...auroraTempo User Guide 1 16 423972 ...
Page 35: ...Issue 1a 10 99 3 3 Getting Started Connecting auroraTempo within the Frame Relay Network ...
Page 48: ...auroraTempo User Guide 3 16 423972 ...
Page 56: ...auroraTempo User Guide 4 8 423972 The following table provides a key to the T1 display ...
Page 80: ...auroraTempo User Guide 4 32 423972 ...
Page 110: ...auroraTempo User Guide 5 30 423972 ...
Page 178: ...auroraTempo User Guide 5 98 423972 ...
Page 197: ...Issue 1a 10 99 6 19 Configuring auroraTempo ...
Page 198: ...auroraTempo User Guide 6 20 423972 ...
Page 202: ...auroraTempo User Guide 6 24 423972 ...
Page 214: ...auroraTempo User Guide 7 12 423972 ...
Page 236: ...auroraTempo User Guide 8 22 423972 ...
Page 242: ...auroraTempo User Guide A1 6 423972 34 Way MRAC Winchester Connector Male Part number 423355 ...
Page 252: ...auroraTempo User Guide A1 16 423972 ...
Page 262: ...auroraTempo User Guide A3 2 423972 Appendix 3 Menutrees Main Menu Menutree ...
Page 265: ...Issue 1a 10 99 A3 5 Appendix 3 Menutrees Setup Config Menutree ...
Page 266: ...auroraTempo User Guide A3 6 423972 ...
Page 267: ...Issue 1a 10 99 A4 1 Appendix 4 Glossary Appendix 4 Contents Glossary A4 2 ...
Page 280: ...auroraTempo User Guide A4 14 423972 ...
Page 284: ...auroraTempo User Guide A5 4 423972 ...
Page 285: ...Issue 1a 10 99 Index 1 Index ...