Installing the System
Installing Additional Components
Chapter 3
88
Figure 3-31 Inserting DIMM into Connector
Step 6.
Replace the memory airflow guide. (See “Replacing the Memory Airflow Guide” on page 80.)
Step 7.
Replace the server cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server”
on page 64.)
Step 8.
Reconnect all power and external cables and turn on the server.
Step 9.
Verify the memory installation by using the system utilities.
•
Use the iLO MP commands to verify operation.
•
Use the BCH commands to verify operation.
•
Use diagnostics provided by the offline diagnostic environment (ODE) to exercise the memory
added.
Removing and Replacing the PCI Card Cage
Accessory cards are installed in a removable PCI card cage. This section explains how to remove and replace
the PCI card cage. Removal is required to install accessory cards.
Removing the PCI Card Cage
To remove the PCI card cage from the server, follow these steps:
Step 1.
Remove the cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server” on
page 64.)
Step 2.
Disconnect the cables from the PCI cards.
Summary of Contents for 9000 rp3410
Page 8: ...Contents 8 ...
Page 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Page 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Page 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Page 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Page 248: ...Appendix B Utilities iLO MP 248 ...
Page 250: ...Physical and Environmental Specifications Appendix C 250 ...