Chapter 1
Overview
Powering the Server On and Off
46
Step 1.
Gracefully shut down the operating system.
Step 2.
Initiate a console session, and access the
MP Main Menu
.
Step 3.
Enter
CM
to enable command mode.
Step 4.
Enter
PC
to use the remote power control command.
Step 5.
Enter
OFF
to power off the server, and enter
YES
when prompted to confirm the action.
IMPORTANT
The main dc voltage is now removed from the system; however, ac voltage for
standby power is still present in the server.
Step 6.
Unplug all power cables from the receptacles on the rear panel of the server.
Powering Off the Server Manually
To manually power off the server, follow these steps:
Step 1.
Gracefully shut down the operating system.
Step 2.
Press the power button to power off the server.
IMPORTANT
The main dc voltage is now removed from the system; however, ac voltage for
standby power is still present in the server.
Step 3.
Unplug all power cables from the receptacles on the rear panel of the server.