Appendix C
249
C
Physical and Environmental Specifications
Table C-1 provides temperature and airflow information for minimum, typical, and maximum configurations
for the HP 9000 rp3410 and rp3440 servers. It also lists the server and rack weights and dimensions.
Table C-1
Physical and Environmental Specifications
Condition
Weight
Overall Server
(W x D x H)
Typical
Heat
Release
Airflow, Nominal
Airflow, at
Maximum
Ambient
degrees C
a
a.
Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.
100-250
VAC
Server
Alone
Rack
Pede-
stal
Rack
Pede-
stal
Min.
Config.
341 Watts
57.8
CFM
98.3
m
3
/hr
68.2
CFM
115.94
m
3
/hr
38.6 lbs
(17.5 kg)
49.0 lbs
(22.2 kg)
56.3 lbs
(25.5 kg)
W: 19.0 in
(48.3 cm)
D: 26.8 in
(67.9 cm)
H: 3.4 in
(8.6 cm)
W: 11.6 in
(29.5 cm)
D: 26.6 in
(67.5 cm)
H: 19.5 in
(49.4 cm)
Max.
Config.
536 Watts
Typical
Config.
426 Watts
ASHRAE
Class 1
Airflow cooling scheme (front to
rear)
Min./
Config.
One dual-core CPU, one power supply, 2 GB
DIMM, zero DVD, three HDDs.
Max.
Config.
Two dual-core CPUs, one power supply, 32 GB
DIMM, one DVD, three HDDs, one graphics card,
one SCSI card.
Typical
Config.
One dual-core CPU, one power supply, 6 GB
DIMM, one DVD, three HDDs, one graphics card,
one SCSI card.
Summary of Contents for 9000 rp3410
Page 8: ...Contents 8 ...
Page 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Page 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Page 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Page 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Page 248: ...Appendix B Utilities iLO MP 248 ...
Page 250: ...Physical and Environmental Specifications Appendix C 250 ...