Chapter 6
Removing and Replacing Components
Required Service Tools
148
•
If installing an assembly that is not hot-swappable, disconnect the power cables from the server external
power connectors.
WARNING
Ensure that the server is powered off and all power sources have been
disconnected from the server before working with the server.
Voltages are present at various locations within the server whenever an ac
power source is connected. This voltage is present even when the main power
switch is in the off position.
Failure to observe this warning can result in personal injury or damage to
equipment.
•
Do not wear loose clothing that can snag or catch on the server or on other items.
•
Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.
•
If installing an internal assembly, wear an antistatic wrist strap and use a grounding mat, such as those
included in the Electrically Conductive Field Service Grounding Kit (HP 9300-1155).
•
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards.
Required Service Tools
Service of this product may require one or more of the following tools:
•
Electrically Conductive Field Service Kit (HP part number 9300-1155)
•
1/4 inch flat blade screwdriver
•
ACX-15 Torx® screwdriver
•
Special processor tool kit (HP part number 5069-5441)
Summary of Contents for 9000 rp3410
Page 8: ...Contents 8 ...
Page 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Page 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Page 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Page 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Page 248: ...Appendix B Utilities iLO MP 248 ...
Page 250: ...Physical and Environmental Specifications Appendix C 250 ...