System Specifications
Environmental Specifications
Chapter 2
51
Power and Cooling
Typical power consumption for a server is 600W/2050 Btu/h. The power consumptions listed in Table 2-5 are
valid for a standard configuration as shipped (one 1 GHz processor, 6 GB of memory, 650W power supply,
three hard disk drives, one graphics card, one LVD SCSI card).
All information in this section is based on primary power consumptions.
Table 2-5 lists additional component power consumption information.
Environmental Specifications
This section provides the temperature and humidity requirements, noise emission, and air flow specifications
for the server.
Operating temperature and humidity ranges might vary depending on the installed mass storage devices.
High humidity levels can cause improper disk operation. Low humidity levels can aggravate static electricity
problems and cause excessive wear of the disk surface.
Table 2-6 lists the environmental specifications for a system processing unit with a hard disk drive.
Table 2-5
Additional Component Power Consumption
Additional Component
Power Consumption
Processor
130W
443.6 Btu/h
SCSI hard disk drive (with I/O access)
23W
78.4 Btu/h
SCSI hard disk drive (idle)
16W
54.5 Btu/h
PCI card
10W to 25W
34.12 Btu/h to 85.30 Btu/h
Table 2-6
Environmental Specifications
Parameter
Value
Operating temperature
+5°C to +35°C (+40°F to +95°F)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
Over-temperature shutdown
+40°C (+104°F)
Operating humidity
15% to 80% relative (noncondensing)
Storage humidity
8% to 85% relative (noncondensing)
Acoustic noise emission (ISO 7779)
Sound power level
a
Pedestal system
Typical configuration (disk idle)
b
LwA = 5.1 BA
Maximum configuration (disk idle)
c
LwA = 5.4 BA
Summary of Contents for 9000 rp3410
Page 8: ...Contents 8 ...
Page 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Page 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Page 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Page 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Page 248: ...Appendix B Utilities iLO MP 248 ...
Page 250: ...Physical and Environmental Specifications Appendix C 250 ...