Installing the System
Connecting the Cables
Chapter 3
106
Applying Standby Power to the Server
To apply standby power to the server, follow these steps:
Step 1.
If the server has one power supply installed in slot P1, plug the power cord into that receptacle.
Plug the other end of the power cord into an appropriate outlet.
NOTE
The LED on the power supply does not illuminate in the standby power state. The
LED illuminates when the server is powered on to full power. If the power restore
feature is set to Always On through the iLO MP
PR
command, the server
automatically powers on to the full power state when the power cord is plugged into
the server.
Step 2.
If the server has two power supplies, plug the second power cord into the power supply in slot P2.
Plug the other end of the power cord into an appropriate outlet.
Connecting to the LAN
The server has the following ports that provide network connectivity:
•
iLO MP LAN port. Use this port to access the iLO MP through the LAN.
•
Console/Remote/UPS port (RS-232). Use this port to access the iLO MP through the console.
Figure 3-48 shows the LAN ports on the server rear.
Figure 3-48
LAN Ports on Server Rear
To enable general network connectivity for the server, follow these steps:
Step 1.
Obtain a valid IP address for each LAN port you plan to activate.
Step 2.
Connect the LAN cable from an available LAN port into a live connection on the network.
iLO MP LAN Port
(10/100 LAN Cable)
10/100/1000 LAN Port
VGA Port-disabled
DO NOT USE
USB Ports (Windows)
Mouse & Keyboard
Serial A/Console Port (factory use only)
Serial B/Console Port (factory use only)
Console/Remote/UPS Port
(M Cable & RS-232 DB-9F to DB-9F)
Summary of Contents for 9000 rp3410
Page 8: ...Contents 8 ...
Page 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Page 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Page 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Page 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Page 248: ...Appendix B Utilities iLO MP 248 ...
Page 250: ...Physical and Environmental Specifications Appendix C 250 ...