![HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure User Manual Download Page 319](http://html.mh-extra.com/html/hp/418800-b21-storageworks-modular-smart-array-70-storage-enclosure/418800-b21-storageworks-modular-smart-array-70-storage-enclosure_user-manual_155409319.webp)
Syntax and arguments
When initially inserted into a job, the command syntax and default arguments are:
SetHostDiskDeviceWriteCacheMode ( %hoststorvol_unc_name%, WRITE_CACHE_ENABLED, NOWAIT )
UNC Host Disk Device Name
(%hoststorvol_unc_name%). Select or enter the name of the host disk device
whose write cache mode is to be set.
Write Cache Mode
. Select the write cache mode for the host volume. Choices are
write_cache_enabled
,
and
write_cache_disabled
.
Wait Flag
. Select
wait
or
nowait.
See jobs
wait/no wait
argument.
Examples
AIX
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\/dev/dsk/hd1", WRITE_CACHE_EN-
ABLED, NOWAIT )
HP-UX
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\/dev/dsk/c2t0d2",
WRITE_CACHE_ENABLED, NOWAIT )
Linux
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\/dev/sda3", WRITE_CACHE_EN-
ABLED, NOWAIT )
OpenVMS
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\CATS", WRITE_CACHE_ENABLED,
NOWAIT )
Solaris
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\/dev/dsk/c0t5d0s6",
WRITE_CACHE_ENABLED, NOWAIT )
Tru64 UNIX
SetHostDiskDeviceWriteCacheMode ( \\HostA2\/dev/disk/dsk100c",
WRITE_CACHE_ENABLED, NOWAIT )
Windows
SetHostDiskDeviceWriteCacheMode ( "\\HostA2\Disk3", WRITE_CACHE_ENABLED,
NOWAIT )
Comments
•
Associated validation commands
.
ValidateHost
.
•
Agent and license prerequisites
. Requires a host agent.
•
Command result value
. None. For a complete list, see
command result values
.
•
OS speci
fi
cs
. Yes. See examples above.
•
See
resource names and UNC formats
.
SetHostVolumeGroupWriteCacheMode
Enables or disables (stops and
fl
ushes) the write cache of the storage volumes (virtual disks) that underlie
a host volume group.
When the job is run, the virtual disk write cache mode is enabled or disabled as speci
fi
ed. If the write
cache mode is already as speci
fi
ed, no change in operation occurs.
HP StorageWorks Replication Solutions Manager 4.0.1
319
Summary of Contents for 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure
Page 16: ...Tables 1 Document conventions 18 16 ...
Page 20: ...20 About this guide ...
Page 56: ...56 Replication Solutions Manager ...
Page 160: ...160 Host volumes ...
Page 384: ...384 Managed sets ...
Page 402: ...402 Oracle ...
Page 412: ...412 Storage systems ...
Page 444: ...444 Virtual disks ...
Page 456: ...456 CLUI ...