
Index
32768 samples, 1–3 to 1–4
8-bit vertical voltage resolution, 8–7
A
Accumulate display Mode
See Display Mode, 7–5
acquisition memory
in repetitive run mode, 1–4
in single run mode, 1–3
acquisition memory sections, 4–7
Acquisition Time field, 7–8
acquisition time vs sweep time, 4–4
adding channels to the display, 9–9
at Level field, 5–12
at Level field percentage, 5–12
attenuation
See probe attenuation
auto markers pop-up menu options,
default, 5–10
Auto-Measure menu, 8–2
Auto-Trig field, 6–10, 6–17
Auto-Trig Off field, when to use, 6–10
automatic markers
Run Until Time X-O field, 5–15 to 5–16
Slope field default, 5–13
at Level field, 5–12
at Level field default value, 5–12
Occur field, 5–13
Occur field, default value, 5–13
Run Until Time X- O field default, 5–15
Set on field, 5–11
Set on field default, 5–11
Slope field, 5–13
Statistics field, 5–14
type absolute, 5–12
type percent, 5–12
automatic measurements
+Width, 8–9
-Width, 8–9
algorithms, 8–7
See also Auto-Measure
criteria used to make measurements, 8–6
display, 8–4
Falltime, 8–10
Frequency, 8–8
Input field, 8–4
measurement setup requirements, 8–5
measurements available, 8–2
Overshoot, 8–10
Period, 8–8
prerequisites, 8–5
Preshoot, 8–10
Risetime, 8–9
things to remember, 8–5
top and base voltages, 8–7
Vp_p, 8–8
automatic measurements display, 8–4
automatic time markers
percentage of top-to-base voltage value,
5–10
automatic/manual markers
setting, 5–17
autoscale, 2–2
algorithm, 2–4 to 2–5
cancel, 2–3
continue, 2–2 to 2–3
displaying the waveform, 2–5
finding the time base settings, 2–4
finding the vertical settings, 2–4
settings changed by, 2–6
trigger point location, 2–5
when a signal cannot be found, 2–5
autoscale field options, 2–3
autoscale run, 1–3
Average display mode
See Display Mode
B
base and top voltages, 8–7
C
Calibration, 11–9
cancel option of autoscale, 2–3
cancel option of run, 1–4
center screen field, 5–21
Channel
deleting, 9–10
Input field, 3–4
input identification, 3–4
inserting, 9–9
channel label field, 5–8
Channel menu map, 3–2
Channel/Pattern field, 6–12
cleaning, 11–8
Connect Dots field, 7–6
continue option of autoscale, 2–3
continue option of autoscale field, 2–2
Count Field, 6–16
Coupling field
default value, 3–7
selections, 3–7
setting input impedance, 3–7
D
Data acquired at field, 4–8
data points displayed on the horizontal
axis, 8–7
Delay field, 4–5 to 4–7
default value, 4–6
delay range, 4–6
delay time
definition, 4–5
from trigger point, 4–5
reference point, 4–5
resolution, 4–6
delay-by-events triggering, 6–9
deleting channels from the display, 9–10
deleting waveforms from the display, 9–10
Display
Connect Dots field, 7–6
overlaying channels, 9–5
display divisions
horizontal, 4–3
vertical, 3–5 to 3–6
Display Mode
Accumulate, 7–5
Average, 7–4
Normal, 7–4
selections, 7–4
display options, 7–2
display, sample period value, 4–9
display, time marker value, 5–9
display, voltage marker value, 5–22
dotted vertical red line, 6–4
Index-1
Summary of Contents for 16533A
Page 6: ...vi ...
Page 11: ...1 Run Stop Options ...
Page 15: ...2 Autoscale ...
Page 21: ...3 The Channel Menu ...
Page 23: ...Channel Field Menu Map The Channel Menu 3 3 ...
Page 29: ...4 Time Base Functions ...
Page 42: ...4 14 ...
Page 43: ...5 The Marker Menu ...
Page 45: ...Markers Field Menu Map The Marker Menu 5 3 ...
Page 46: ...Markers Field Menu Map Continued The Marker Menu 5 4 ...
Page 65: ...6 The Trigger Menu ...
Page 67: ...Trigger Field Menu Map The Trigger Menu 6 3 ...
Page 84: ...6 20 ...
Page 85: ...7 The Display Menu ...
Page 87: ...Display Field Menu Map The Display Menu 7 3 ...
Page 94: ...7 10 ...
Page 95: ...8 The Auto Measure Menu ...
Page 97: ...Auto Measure Menu Map The Auto Measure Menu 8 3 ...
Page 105: ...9 The Waveform Selection Menu ...
Page 107: ...Waveform Selection Menu Map The Waveform Selection Menu 9 3 ...
Page 116: ...9 12 ...
Page 117: ...10 Specifications and Characteristics ...
Page 125: ...11 Installation and Operator s Service ...
Page 140: ...11 16 ...
Page 148: ...Glossary 4 ...