272
Comware software upgrade examples
Using XMODEM to upgrade software through the console
port
1.
In the EXTENDED-BOOTWARE menu, enter
2
.
The Serial submenu appears:
===========================<Enter Serial SubMenu>===========================
|Note:the operating device is flash |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Download Files(*.*) |
|<5> Modify Serial Interface Parameter |
|<0> Exit To Main Menu |
============================================================================
Enter your choice(0-5):
2.
In the Serial submenu, enter
5
.
===============================<BAUDRATE SET>=============================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Available>---------------------------|
|<1> 9600(Default)* |
|<2> 19200 |
|<3> 38400 |
|<4> 57600 |
|<5> 115200 |
|<0> Exit |
==========================================================================
Enter your choice(0-5):1
3.
Select the correct download baud rate.
In this example, enter
1
to select 9600 bps.
4.
Change the baud rate of your terminal to match the setting on the Serial submenu. Then, close
your connection to the device and reestablish the connection to make the terminal's baud rate
change take effect. Finally, press
Enter
.
The Serial submenu appears again:
===========================<Enter Serial SubMenu>===========================
|Note:the operating device is flash |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Download Files(*.*) |
|<5> Modify Serial Interface Parameter |
|<0> Exit To Main Menu |
============================================================================
Enter your choice(0-5): 2
Summary of Contents for FlexNetwork 10500 Series
Page 139: ...130 Sysname display version ...