209
Step
Command
Remarks
3.
Set the free-memory
thresholds.
•
In standalone mode:
memory-threshold
[
slot
slot-number
[
cpu
cpu-number
] ]
[
ratio
]
minor minor-value severe
severe-value critical critical-value
normal normal-value
•
In IRF mode:
memory-threshold
[
chassis
chassis-number
slot
slot-number
[
cpu
cpu-number
] ]
[
ratio
]
minor
minor-value severe severe-value
critical critical-value normal
normal-value
The defaults are as follows:
•
Minor alarm threshold
—96
MB.
•
Severe alarm threshold
—64
MB.
•
Critical alarm threshold
—48
MB.
•
Normal state threshold
—128
MB.
Configuring the temperature alarm thresholds
The device monitors its temperature based on the following thresholds:
•
Low-temperature threshold.
•
High-temperature warning threshold.
•
High-temperature alarming threshold.
•
When the temperature drops below the low-temperature threshold or reaches the
high-temperature warning threshold, the device sends a log message and a trap.
When the temperature reaches the high-temperature alarming threshold, the device repeatedly
sends log messages and traps, and sets the LEDs on the device panel.
This feature is supported only on the default MDC.
To configure the temperature alarm thresholds:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the temperature
alarm thresholds.
•
In standalone mode:
temperature-limit
slot
slot-number
{
hotspot
|
inflow
|
outflow
}
sensor-number
lowlimit
warninglimit
[
alarmlimit
]
•
In IRF mode:
temperature-limit
chassis
chassis-number
slot
slot-number
{
hotspot
|
inflow
|
outflow
}
sensor-number
lowlimit
warninglimit
[
alarmlimit
]
To view the default thresholds,
use the
undo
form of the
command to restore the default
and execute the
display
environment
command.
The high-temperature alarming
threshold must be higher than the
high-temperature warning
threshold. The high-temperature
warning threshold must be higher
than the low-temperature
threshold.
Specifying load sharing modes for a service
module
shows the default load sharing modes for service modules. You can specify load sharing
modes as required.
Summary of Contents for FlexNetwork 10500 Series
Page 139: ...130 Sysname display version ...