207
To monitor CPU usage in IRF mode:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Set the CPU usage
threshold.
monitor cpu-usage threshold
cpu-threshold
[
chassis
chassis-number slot
slot-number
[
cpu
cpu-number
] ]
The default CPU usage threshold
is 99%.
3.
Enable CPU usage tracking.
monitor cpu-usage enable
[
chassis
chassis-number slot
slot-number
[
cpu
cpu-number
] ]
By default, CPU usage tracking is
enabled.
4.
Set the sampling interval for
CPU usage tracking.
monitor cpu-usage interval
interval-value
[
chassis
chassis-number slot
slot-number
[
cpu
cpu-number
] ]
By default, the sampling interval
for CPU usage tracking is 1
minute.
5.
Exit to user view.
quit
N/A
6.
Display CPU usage
statistics.
display cpu-usage
[
summary
]
[
chassis
chassis-number
slot
slot-number
[
cpu
cpu-number
] ]
This command is available in any
view.
7.
Display CPU usage
monitoring settings.
display cpu-usage
configuration
[
chassis
chassis-number slot
slot-number
[
cpu
cpu-number
] ]
This command is available in any
view.
8.
Display the historical CPU
usage statistics in a
coordinate system.
display cpu-usage history
[
job
job-id
]
[
chassis
chassis-number
slot slot-number
[
cpu
cpu-number
] ]
This command is available in any
view.
Setting memory alarm thresholds
To monitor memory usage, the device performs the following operations:
•
Samples memory usage at an interval of 1 minute, and compares the sample with the memory
usage threshold. If the sample is greater, the device sends a trap.
•
Monitors the amount of free memory space in real time. If a free-memory threshold is exceeded,
the system generates an alarm notification or an alarm-removed notification and sends it to
affected service modules or processes.
, the system supports the following free-memory thresholds:
•
Normal state threshold.
•
Minor alarm threshold.
•
Severe alarm threshold.
•
Critical alarm threshold.
Table 16 Memory alarm notifications and memory alarm-removed notifications
Notification
Triggering condition
Remarks
Minor alarm notification
The amount of free memory
space decreases to or below the
minor alarm threshold for the first
time.
After generating and sending a minor alarm
notification, the system does not generate
and send any additional minor alarm
notifications until the first minor alarm is
removed.