148
Verifying the file flash:/feature1-r0202.bin on Chassis 1 slot 7...Done.
Upgrade summary according to following table:
flash:/feature1-r0202.bin
Running Version New Version
Alpha 0201 Alpha 0202
Chassis Slot Upgrade Way
1 6 Reboot
1 7 Reboot
Upgrading software images to incompatible versions. Continue? [Y/N]: y
This operation might take several minutes, please wait...Done.
# Verify that both members are running the new feature image.
<Sysname> display install active
Active packages on chassis 1 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 1 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 2 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 2 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Examples of using issu commands for ISSU on a
four-member IRF fabric
Feature upgrade to a compatible version
Upgrade requirements
As shown in
, the IRF fabric has four members. Each member has one active MPU (slot 6),
one standby MPU (slot 7), and one LPU (slot 3).
Upgrade a feature from soft-version1 to soft-version2 on the IRF fabric. The two versions are
compatible.
Summary of Contents for FlexNetwork 10500 Series