208
Notification
Triggering condition
Remarks
Severe alarm notification
The amount of free memory
space decreases to or below the
severe alarm threshold for the
first time.
After generating and sending a severe
alarm notification, the system does not
generate and send any additional severe
alarm notifications until the first severe
alarm is removed.
Critical alarm notification
The amount of free memory
space decreases to or below the
critical alarm threshold for the
first time.
After generating and sending a critical
alarm notification, the system does not
generate and send any additional critical
alarm notifications until the first critical
alarm is removed.
Critical alarm-removed
notification
The amount of free memory
space increases to or above the
severe alarm threshold.
N/A
Severe alarm-removed
notification
The amount of free memory
space increases to or above the
minor alarm threshold.
N/A
Minor alarm-removed
notification
The amount of free memory
space increases to or above the
normal state threshold.
N/A
Figure 47 Memory alarm notifications and alarm-removed notifications
To set memory alarm thresholds:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Set the memory
usage threshold.
•
In standalone mode:
memory-threshold
[
slot
slot-number
[
cpu
cpu-number
] ]
usage memory-threshold
•
In IRF mode:
memory-threshold
[
chassis
chassis-number
slot
slot-number
[
cpu
cpu-number
] ]
usage
memory-threshold
The default memory usage
threshold is 100%.
Minor
Critical
Free memory space
Severe
Normal
Minor alarm-removed
Severe alarm-removed
Time
Minor
alarm
Severe alarm
Critical alarm
Critical alarm-removed