162
# Enable link-aggregation traffic redirection.
[Sysname] link-aggregation lacp traffic-redirect-notification enable
# Enable the IRF bridge MAC address to be permanent.
[Sysname] irf mac-address persistent always
# Set the physical state change suppression interval to 0 on the interfaces.
[Sysname] interface gigabitethernet1/3/0/1
[Sysname-GigabitEthernet1/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet1/3/0/1] quit
[Sysname] interface gigabitethernet2/3/0/1
[Sysname-GigabitEthernet2/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet2/3/0/1] quit
[Sysname] interface gigabitethernet3/3/0/1
[Sysname-GigabitEthernet3/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet3/3/0/1] quit
[Sysname] interface gigabitethernet4/3/0/1
[Sysname-GigabitEthernet4/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet4/3/0/1] quit
[Sysname] quit
# Upgrade the feature on all subordinate members. After the upgrade, the subordinate members will
leave the original IRF fabric and form a new IRF fabric.
<Sysname> issu load file feature flash:/soft-version2.bin chassis 2 3 4
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Verifying the file flash:/soft-version2.bin on chassis 1 slot 6...Done
.
Copying file flash:/soft-version2.bin to chassis2#slot6#flash:/soft-version2.bin
...Done.
Copying file flash:/soft-version2.bin to chassis2#slot7#flash:/soft-version2.bin
...Done.
Copying file flash:/soft-version2.bin to chassis3#slot6#flash:/soft-version2.bin
...Done.
Copying file flash:/soft-version2.bin to chassis3#slot7#flash:/soft-version2.bin
...Done.
Copying file flash:/soft-version2.bin to chassis4#slot6#flash:/soft-version2.bin
...Done.
Copying file flash:/soft-version2.bin to chassis4#slot7#flash:/soft-version2.bin
...Done.
Verifying the file flash:/soft-version2.bin on chassis 2 slot 6............Done.
Verifying the file flash:/soft-version2.bin on chassis 2 slot 7............Done.
Verifying the file flash:/soft-version2.bin on chassis 3 slot 6............Done.
Verifying the file flash:/soft-version2.bin on chassis 3 slot 7............Done.
Verifying the file flash:/soft-version2.bin on chassis 4 slot 6............Done.
Verifying the file flash:/soft-version2.bin on chassis 4 slot 7............Done.
Upgrade summary according to following table:
flash:/soft-version2.bin
Running Version New Version
Release 7168 Release 7168
Summary of Contents for FlexNetwork 10500 Series
Page 139: ...130 Sysname display version ...