242
============================================================================
Enter your choice(0-5):1
3.
Enter an appropriate baud rate option. For example, enter
5
to set the baud rate to 115200 bps.
For faster file transfer, change the default baud rate to a higher value before downloading
Comware software with XMODEM through the console port.
4.
Enter
0
to return to the Serial submenu.
5.
Choose an option from
1
to
3
. For example, to upgrade the main Comware software images,
enter
2
.
6.
On the configuration terminal, configure the communication settings and transfer the upgrade
file. For more information, see "
Using XMODEM to upgrade software through the console port
In this example, the system sets the file as a main software image file when the file transfer is
complete. The following is the sample output:
Waiting ...CCC
Download successfully!
47979456 bytes downloaded!
Updating File
flash:/test-boot-r7328.bin..............................................
..Done.
7.
Enter
0
in the Serial submenu to return to the EXTENDED-BOOTWARE menu.
8.
Enter
1
in the EXTENDED-BOOTWARE menu to run the new software.
Upgrading Comware software through the management
Ethernet port
You can upgrade the Comware software through the management Ethernet port from the Ethernet
submenu.
To upgrade Comware software through the management Ethernet port from the Ethernet submenu:
1.
Enter
3
in the EXTENDED-BOOTWARE menu to access the Ethernet submenu.
==========================<Enter Ethernet SubMenu>==========================
|Note:the operating device is flash |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Download Files(*.*) |
|<5> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
|<Ensure The Parameter Be Modified Before Downloading!> |
============================================================================
Enter your choice(0-5):
Table 33 Ethernet submenu options
Option
Task
<1> Download Image Program To SDRAM
And Run
Load and run Comware software images in SDRAM.
This option is only available when password recovery
capability is enabled.