168
<Sysname> install add flash:/feature1-r0202.ipe flash:
Verifying the file flash:/feature1-r0202.ipe on chassis 1 slot 6...Done.
Decompressing file feature1-r0202.bin to
flash:/feature1-r0202.bin.......................Done.
# Display active software images.
<Sysname> display install active
Active packages on chassis 1 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0201.bin
Active packages on chassis 1 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0201.bin
Active packages on chassis 2 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0201.bin
Active packages on chassis 2 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0201.bin
# Identify the recommended ISSU methods for the upgrade and view the possible impact of the
upgrade.
<Sysname> install activate feature flash:/feature1-r0202.bin chassis 2 slot 7 test
Copying file flash:/feature1-r0202.bin to
chassis2#slot7#flash:/feature1-r0202.bin......Done.
Verifying the file flash:/feature1-r0202.bin on chassis 2 slot 7...Done.
Upgrade summary according to following table:
flash:/feature1-r0202.bin
Running Version New Version
Alpha 0201 Alpha 0202
Chassis Slot Upgrade Way
2 6 Service Upgrade
2 7 Service Upgrade
Influenced service according to following table on chassis 2 slot 6:
flash:/feature1-r0202.bin
feature1 CFA
Influenced service according to following table on chassis 2 slot 7:
flash:/feature1-r0202.bin
feature1 CFA
<Sysname> install activate feature flash:/feature1-r0202.bin chassis 2 slot 6 test
Copying file flash:/feature1-r0202.bin to
chassis2#slot6#flash:/feature1-r0202.bin......Done.
Verifying the file flash:/feature1-r0202.bin on chassis 2 slot 6...Done.
Upgrade summary according to following table:
Summary of Contents for FlexNetwork 10500 Series
Page 139: ...130 Sysname display version ...