145
flash:/feature1-r0202.bin
Running Version New Version
Alpha 0201 Alpha 0202
Chassis Slot Upgrade Way
1 6 Service Upgrade
1 7 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]: y
This operation might take several minutes, please wait...Done.
# Verify that both members are running the new feature image.
<Sysname> display install active
Active packages on chassis 1 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 1 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 2 slot 6:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Active packages on chassis 2 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0202.bin
Feature upgrade to an incompatible version
Upgrade requirements
As shown in
, the IRF fabric has two members. Each member has one MPU in slot 6 (active
MPU) and one MPU in slot 7 (standby MPU).
Upgrade the feature1 feature from R0201 to R0202. The two versions are incompatible.
Summary of Contents for FlexNetwork 10500 Series
Page 139: ...130 Sysname display version ...