233
For faster file transfer, change the default baud rate to a higher value before downloading a software
image file with XMODEM through the console port.
To change the baud rate of the console port:
1.
Enter
1
in the BASIC-BOOTWARE menu.
Enter your choice(0-5): 1
===============================<BAUDRATE SET>===============================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Available>---------------------------|
|<1> 9600(Default)* |
|<2> 19200 |
|<3> 38400 |
|<4> 57600 |
|<5> 115200 |
|<0> Exit |
============================================================================
Enter your choice(0-5):
2.
Enter the number that represents the baud rate you want to choose. For example, enter
5
to set
the baud rate to 115200 bps.
NOTE:
The baud rate change is a one-time operation. The baud rate will restore to the default (9600 bps) at
reboot. To establish a console session with the device after a reboot, you must change the baud rate
setting on the configuration terminal to 9600 bps.
Updating the extended BootWare segment
If the extended BootWare segment is corrupt, enter
2
in the BASIC-BOOTWARE menu to update it.
Enter your choice(0-5): 2
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCC
Download successfully!
329344 bytes downloaded!
Updating Extended BootWare? [Y/N]Y
Updating Extended BootWare...............Done.
Updating the entire BootWare
To update the entire BootWare, enter
3
in the BASIC-BOOTWARE menu.
Enter your choice(0-5): 3
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCC
Download successfully!
329344 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare...............Done.
Updating Extended BootWare? [Y/N]Y
Updating Extended BootWare...............Done.