rbidity meter HU-200TB-W SS-120-W Operation procedure 7
(Change the mode
and settings
)
LC
D ch
eck scr
een
T
he whole LCD
light
s up to find defe
ct
s of
the
display p
anel.
Re
lay output 1
check scree
n
T
he ON/OFF st
atu
s for
relay 1 (r1
) can be
checked
.
Re
lay output 2
check scree
n
T
he ON/OFF st
atu
s for
relay 2 (r2
) can be
checked
.
Re
lay output 3
check scree
n
T
he ON/OFF st
atu
s for
relay 3 (r3
) can be
checked
.
FA
IL output
check scree
n
The ON/OF
F
st
atus of F
A
IL can be
ch
ecked.
Range cont
a
ct ou
tput 1 check scr
een
The
ON
/OFF st
atu
s f
or ran
ge con
tact ou
tpu
t
1 can be checked.
Range cont
a
ct ou
tput 2 check scr
een
The
ON
/OFF st
atu
s f
or ran
ge con
tact ou
tpu
t
2 can be checked.
Scr
een for
checking
electric ball valve
output fo
r sample w
ater line
The e
lectric ball valve oper
atio
n can
be
ch
ecked.
Scr
een for
checking
solenoid valve output
for zero water
line
The solenoid va
lve oper
ation
can b
e
ch
ecked.
T
ransmission outp
ut che
ck scr
een
3.8 mA is ou
tput to the tr
ansmission out
put.
T
ransmission outp
ut che
ck scr
een
4 mA is outp
ut to the tr
ansmission outpu
t.
T
ransmission outp
ut che
ck scr
een
12 mA is out
put to the tr
ansmission outp
ut.
T
ransmission outp
ut che
ck scr
een
20 mA is out
put to the tr
ansmission outp
ut.
T
ransmission outp
ut che
ck scr
een
21 mA is out
put to the tr
ansmission outp
ut.
Exter
nal con
tact
input check screen
When 1, 2, 3,
and 4 are
inpu
t, in th
is order
from th
e lef
t, 1 is disp
layed.
Initialization screen
for setup
dat
a a
nd sp
an
ca
libration dat
a
In
itialization
scr
een for the set
up
da
ta
a
nd
ca
libration dat
a
Select “yES” with
/
, and th
en press
ENT
to i
nitial
iz
e.
Us
er check
men
u
Go to th
e right p
art
Manual zer
o calibration
Zer
o calibration is an
operation that
adjust
s the
value of clean water
to zero.
S
pan
calib
ration
Adjust th
e cu
rr
en
t va
lue to th
e
turbidity of th
e st
andard
solution.
Dat
a shif
t by adjust
Y
ou can shif
t the measur
ed
value.
Manual inpu
t of co
ef
ficient
Dat
a will be
gained
in
propor
tion
to the coef
ficie
nt.
Automati
c zer
o cali
bration
Wh
en ENT is presse
d, a
sequ
ential valve oper
ation
and automatic ze
ro calibration
will be perfo
rmed, and
then
the valve will ret
urn to it
s
origina
l condition
.
Cal m
enu
Deter
m
ined
in
Deter
m
ined
in
Deter
m
ined
in
Deter
m
ined
in
Same
as S
pan calibr
ation
o
n the p
age o
ne.
Continuation of the Ope
ration procedur
e 4