![horiba HU-200TB-W SS-120-W Instruction Manual Download Page 106](http://html1.mh-extra.com/html/horiba/hu-200tb-w-ss-120-w/hu-200tb-w-ss-120-w_instruction-manual_2162226106.webp)
Tu
rbidity meter HU-200TB-W SS-120-W Operation procedure 6
(Change the mode
and settings)
T
ransmission ou
tput 2.A value (
full-
scale
ran
ge) setting
Setting rang
e: 10.00, 10
0
.0, 1000
Initial value
: 1000, 100.0
, 10.00
Go to the r
ight
pa
rt
C
ontin
uation
of
th
e previo
us p
age
Zer
o point value
setting for
transmissio
n
output 2
.A
Setting rang
e: 0.00 to 1
1.00, 0.0 to 1
10.0, 0
to 2200
/ Initial value: 0
, 0.0, 0.00
S
pan point value setting for
transmission
ou
tpu
t 2.
A /
Set
ting
range
: 0.
00 t
o 1
1.00,
0.
0
to 1
10
.0, 0 to 2200
Initial value
: 1000, 100.0
, 50.0, 10.00
Automatic cleaner
operation setting
Setting rang
e: yES, no
Initi
al val
ue: no
Cleaning oper
ation t
ype setting
Setting rang
e: nor
, or
, And, t
rg
Initi
al val
ue: or
Cleaning tim
e setting
This is displayed when
“CLn
” is set to “
yES”.
Setting rang
e: 20 to 600 (
s)
Initi
al val
ue: 30
Setting of re
tention
time fo
r tra
nsmission
output h
old af
ter completion
of cleaning
Setting rang
e: 60 to 600 (
s)
Initi
al val
ue: 60
RS-485 address
setting
Setting
range:
0 to 99
Ini
tial v
a
lu
e: 0
Setting
fo
r reversing logic of hold command
(calibra
tion/ho
ld command)
Wh
en “tyPE” of Automa
tic ze
ro calibra
tion
sett
ing is set to
“nor
”, the logic of
the
calibration/hold command is r
ever
sed.
Setting
range:
yES, no
Ini
tial v
a
lu
e: no
Selection of command by cont
act
(calibra
tion/ho
ld command)
Wh
en “tyPE” of Automa
tic ze
ro calibra
tion
sett
ing i
s s
et to “
or”
, “And”, or
“tr
g”, “C
AL” i
s
displaye
d
Setting
range:
C
A
L, HoLd
Ini
tial v
a
lu
e: -
Inter
nal timer
cleaning cycle
setting
This is displayed when
“C
Ln” is set to “
yES”,
and “
tyPE”
of CLn is set to “
nor”
, “or
”, or
“And”
.
Setting rang
e: 0.1 to 168.
0 (h)
Initi
al val
ue: 2.0
T
ransmission ou
tput 2.A hold output value
(preset) setting This is displayed when
“C.HoL
d” is set to
“Pr
E
S.”
Setting rang
e: 0.00 to 1
1.00, 0.0 to 1
10.0, 0
to 2200 Initial value
: 1000, 100.0
, 50.0,10.00
Setting
for r
ever
sing the logic
of hold
comma
nd (clea
ning/h
old command)
Wh
en the clea
ning st
ar
t is set to “n
or”,
the
logic of the cle
aning/
hold command
is
rev
ers
ed.
Setting
range:
yES, no
Ini
tial v
a
lu
e: no
Selection of command by cont
act (clea
ning/
ho
ld c
om
m
and
)
Wh
en “tyPE” of Cleaning oper
ation se
tting
is set to “or”, “And”, or “trg”, “C
Ln” is
displaye
d
Setting
range:
C
Ln, HoLd
Ini
tial v
a
lu
e: -
Settin
g procedur
e
for T
ransmissio
n
output 2b,
2C and
2d are