5-1
S E C T I O N 5
Operation
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
One of the three modes of operation, Manual, LRR Line Card and 685 Automation must be
selected during the 7810iR-ent programming.
Manual Mode
Manual Mode is a standalone method of receiving contact ID messages from a protected
premise. Incoming messages are displayed in ADEMCO high-speed or Contact ID format in
the New Alarm Window of the 7810iR-ent. An operator is required to silence an incoming
alarm and manually move it from the New Alarm window to the Alarm History window
using the GUI.
Both the New Alarm window and the Alarm History window are first-in first-out (FIFO)
buffers that are limited to a total of 49 entries. Once 49 messages have been received in the
New Alarm buffer, the next message received will push the oldest alarm off the list. There is
no method to save or archive messages in these buffers when the 7810iR-ent is being used in
the Manual Mode.
Alarm Sequence in Manual Mode
Action
Screen Display
1. Manual Mode “Home” screen.
2. New alarm received with audio
alert.