7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide
2-2
Power Requirements
The 7810iR-ent requires a 12VDC, 500mA line input.
UL
For UL installations, the DC power supply must be a UL Listed, regulated 12VDC, min. 500mA
Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TRs
powered by a UL1481 Listed UPS with audible and visual indications of switchover to
secondary power.
ULC
For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC,
min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model
7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible
and visual indications of switchover to secondary power.
Manual Mode
General Information
As the name implies, Manual Mode is a standalone method of receiving Contact ID or
ADEMCO high-speed messages from a protected premise. Incoming messages are displayed
in the New Alarm Window of the 7810iR-ent. An operator is required to silence an incoming
alarm and manually move it from the New Alarm window to the Alarm History window
using the appropriate touch keys on the GUI.
A programmable feature allows Manual Mode to be the 7810iR-ent failure mode. When
selected during programming,
Fail to Manual
allows the 7810iR-ent to automatically
revert to Manual Mode if the automation equipment or LRR line card fails.
Fail to Manual
mode must be enabled for UL installations. Refer to Section 5 for a detailed description of
the
Fail to Manual
feature.
Wiring the 7810iR-ent for Manual Mode
There are two methods of powering the 7810iR-ent. You can use a UL Listed, regulated
12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2
Honeywell Model 7720V2TRs powered by a UL1481 Listed UPS. If using Model 7720V2TRs,
refer to Figure 1a, and connect as follows:
1.
Connect the 12V AUX terminal (pin 1) of the 7810iR-ent to the DC (+) terminal of a
7720V2TR power supply.
2.
Connect the 12V IN terminal (pin 2) of the 7810iR-ent to the DC (+) terminal of a second
7720V2TR power supply.
3.
Connect the GND terminal (pin 3, BLK) of the 7810iR-ent to the DC (-) terminal of both
7720V2TR power supplies.
4.
Connect one end of the Ethernet cable (Category 5) to the 7810iR-ent’s RJ45 Ethernet
connector and the other end to an Ethernet router.
UL
For AlarmNet you must use a UL Listed cable/DSL router (externally powered) suited for the
application.
5.
Attach the case front of the 7810iR-ent to the case back. Attach the top of the 7810iR-ent
first, and then press the bottom section inward until it snaps into place securely.
NOTE: For more information on networking, refer to the Communications Setup Section.
For general information on the 7810iR-ent, refer to the Navigation and Basic Features
Section. To complete the installation, refer to the Programming Section.
Summary of Contents for AlarmNet 7810iR-ent
Page 2: ......
Page 22: ...7810iR ent Internet Intranet Alarm Receiver Installation and Setup Guide 3 4 ...
Page 66: ...7810iR ent Internet Intranet Alarm Receiver Installation and Setup Guide 5 10 ...
Page 86: ...7810iR ent Internet Intranet Alarm Receiver Installation and Setup Guide 6 20 ...
Page 97: ...Notes ...
Page 98: ...Notes ...
Page 99: ...Notes ...
Page 100: ...Notes ...
Page 101: ...Notes ...